E6582062
7. Operating using external signals
7-16
4
4
4
7
9
For details on switching two types of analog signals for operation, refer to [5. 4. 1].
Common
F209
Analog input filter
1: Disabled
2 - 1000 (ms)
1
*3
A959
Analog input function target
11
0: Disabled
1: Terminal RR
2: Terminal RX
3: Terminal II
4: Terminal AI4
5: Terminal AI5
A961
Analog function setting
destination 11
0: Disabled
1: Acc/Dec rate (ACC.dEC etc.)
2: Upper limit frequency (UL)
3: Acc multiplication factor (FH/
ACC etc.)
4: Dec multiplication factor (FH/
dEC etc.)
5: Manual torque boost (vb etc.)
6: Stall prevention level (F601 etc.)
7: Motor OL protection current
(tHrA)
8: Speed control response (F460
etc.)
9: Droop gain (F320 etc.)
10: PID proportional gain (F362
etc.)
11: Base frequency voltage (VL
etc.)
12 - 20: -
A962
Analog input function target
21
Same as A959
A964
Analog function setting
destination 21
Same as A961
*1 The default setting value is depending on the setup menu. Refer to [5. 3. 10].
*2 Indicated optional terminals on IO extension 1 (ETB013Z), refer to E6582128.
*3 If stable operation cannot be achieved because of noise of the frequency command circuit, etc., increase the value for <F209: Analog input
filter>.
Terminal
symbol
Title
Parameter name
Adjustment range
Default
setting
Содержание TOSVERT VF-AS3
Страница 2: ...1 9 ...
Страница 14: ......
Страница 17: ...E6582062 iii I 3 9 15 Warranty 15 1 16 Disposal 16 1 ...
Страница 18: ......
Страница 34: ......
Страница 438: ......
Страница 458: ......
Страница 470: ......
Страница 482: ......
Страница 502: ......
Страница 572: ......
Страница 590: ......
Страница 608: ......
Страница 616: ......
Страница 618: ......
Страница 620: ......
Страница 621: ...1 3 9 10 ...