E6582062
6. [Advanced] How to use parameters
6-176
4
4
6
9
6. 34. 10 Setting torque command value in panel run
<F725: Panel torque command>
■
Function
This parameter is used to set a torque command value when torque control is performed in panel
run.
■
Parameter setting
■
Guideline for the setting
<F725: Panel torque command> is enabled only when <F420: Torque command select> is "12" and
acts as command value(%).
For details, refer to torque control (E6582106).
Title
Parameter name
Adjustment range
Unit
Default setting
F725
Panel torque command
-250 to +250
%
0
Reference
• How to operate the operation panel -> Refer to [3. 1. 1].
• How to switch display mode on the operation panel -> Refer to [3. 1. 2].
• Procedure to change parameter setting -> Refer to [4. 2. 3]
• Details on operation by external signals -> Refer to [Chapter 7].
0.0Hz
STOP
14:15
F725 : Panel torque command
Min: -250
Max: 250
X1000
X100
X10
X1
%
+0