background image

Model name

TCB-SC643TLE

Owner’s Manual

Air Conditioning Control System

 Thank you for purchasing this Air Conditioning Control System.

 In order to use this product safely and correctly, please read this operation manual carefully before use and 

make sure that you fully understand the contents.
In particular, please be sure to read the "Safety Precautions".

 After reading this manual, be sure to keep it in a place where the operator of the Unit can always view it.

Central remote controller

Содержание TCB-SC643TLE

Страница 1: ...r to use this product safely and correctly please read this operation manual carefully before use and make sure that you fully understand the contents In particular please be sure to read the Safety Precautions After reading this manual be sure to keep it in a place where the operator of the Unit can always view it Central remote controller ...

Страница 2: ...ioners in a Zone 13 Start Stop Operation of an Individual Air Conditioner 14 Change Settings 15 Change the Temperature 15 Change the Operation Mode such as Cool or Heat 16 Change the Air Volume 17 Change the Air Direction 18 5 Various Functions 19 Timer Operation Off Timer On Timer 19 Set the Time Until Operation Stops or Starts 19 Release Timer 21 Energy saving operation 22 Ventilation Operation ...

Страница 3: ...at Auto Dry Fan Change the Operation Mode such as Cool or Heat P 16 Advanced Usage Please use the following functions as necessary To set start stop timer Timer Operation Off Timer On Timer P 19 Please see the following regarding energy saving operation remote control operation control for each air conditioner and confirmation of model information Energy saving operation P 22 Key lock P 26 Informa...

Страница 4: ...roperty refers to extended damage related to houses household goods livestock or pets etc WARNING Request installation Ask the dealer from whom you purchased the unit or a professional for installation work Installation requires specialised technical expertise If you attempt to perform installation work yourself and perform the work incorrectly it may cause fire electric shock or injury Use specif...

Страница 5: ...malfunction Check the installation location Do not install the air conditioner in a place where combustible gas may leak Gas leaking and accumulating around the product may cause a fire Prohibited Do not drop the product or apply strong shock Doing so may cause a failure If anything is abnormal turn off the power If anything is abnormal stop operation and turn off the original power supply then co...

Страница 6: ...an save energy with the Save Mode for reduced power consumption You can combine with a schedule timer to carry out program operation of the air conditioners The system configurations that this unit can control are as follows Features of this unit System Configurations Zone 1 Central remote controller 10 Zones up to a total of 64 units All Set all air conditioners at once Unit Set the air condition...

Страница 7: ...e dealer from whom you purchased the unit 4 button Press to start operation 5 button Press to stop operation 6 Control button Press to display the Control screen or the Menu screen for controlling air conditioners 7 buttons Press to select setting item 8 Confirm button Press when switching screens from All to Zone to Unit or when selecting an item and going to the next screen 9 Return button Press...

Страница 8: ...d 5 The number of air conditioners in operation is displayed by the ON OFF meter The number of operating air conditioners is indicated by the numbers on the inside of the ON OFF meter No Functions 1 The operation status of the Zone is displayed If you are driving any air conditioners in the Zone is displayed If all air conditioners are stopped is displayed 2 The name of the Zone is displayed 3 Dis...

Страница 9: ...7 You can check and change the air volume P 17 8 You can check and change the operation mode P 16 9 You can check and change the temperature P 15 10 The operation status icon is displayed The Button Operation Guide is also displayed when changing settings such as temperature Icon list 10 6 1 2 3 5 4 7 9 8 ZONE A Cool Next 1 The temperature acquired from the indoor unit is only displayed in Unit Co...

Страница 10: ...Blank spaces cannot be selected The general purpose device control interface is registered The only possible operation is start stop operation When a device other than an air conditioner is connected In the case of Total Heat exchange Ventilation Settings can be done with the menu Menu name Functions Filter Sign Reset Used to cancel the FILTER Sign P 25 The FILTER timer is also reset The FILTER ti...

Страница 11: ...e Control Confirm Return ZONE A ZONE B ZONE C ZONE D ZONE E ZONE F ZONE G ZONE H ZONE I ZONE J All Zone Unit Confirm Return 1 2 3 23 5 C 23 5 C 23 5 C ZONE A ON 2 OFF 1 All Zone Unit Control Return Control Return Control Return All Auto Next Auto Next ZONE A 25 0 C Auto Next 1 01 10 Control Return Control Return Control Return All Menu 1 2 1 Filter Sign Reset 2 Ventilation 3 Off Timer 4 On Timer 5...

Страница 12: ...less etc during operation Cause of failure Start Stop Operation of All Air Conditioners 1 Display the All screen P 11 To start 2 Press The confirmation screen is displayed 3 Press to select Yes then press Confirm All air conditioners start operation and the Run lamp lights up To stop 2 Press The confirmation screen is displayed 3 Press to select Yes then press Confirm All air conditioners stop ope...

Страница 13: ... displayed 4 Press to select Yes then press Confirm All air conditioners in the selected Zone start operation and changes to To stop 3 Press The confirmation screen is displayed 4 Press to select Yes then press Confirm All air conditioners in the selected Zone stop operation and changes to 3 3 2 4 Start Stop ZONE A ZONE B ZONE C ZONE D ZONE E ZONE F ZONE G ZONE H ZONE I ZONE J All Zone Unit ZONE A...

Страница 14: ...nditioner 1 Display the Unit screen P 11 2 Press to select a Zone then press to select an air conditioner To start 3 Press The selected air conditioner starts operation and changes to To stop 3 Press The selected air conditioner stops operation and changes to 3 3 1 2 3 2 23 5 C 23 5 C 23 5 C Start Stop ZONE B ON 2 OFF 1 All Zone Unit 1 2 3 23 5 C 23 5 C 23 5 C All Zone Unit ZONE B ON 2 OFF 1 ...

Страница 15: ...rature that is not supported by an operation mode is set the setting will be ignored If the operation mode is Fan the temperature cannot be set Change Settings Change the Temperature 1 Display the Control screen of All Zone or Unit P 11 2 Press to select the Temperature Settings item 3 Press to change the temperature then press Confirm The temperature can be decreased with and increased with The t...

Страница 16: ...such as Cool or Heat 1 Display the Control screen of All Zone or Unit P 11 2 Press to select the Operation Mode Settings item 3 Press to select the operation mode then press Confirm The selected operation mode is set 2 3 Auto All Next Operation Mode Settings item Auto All Next Dry All Next Return Confirm Icon Operation Mode Auto Heat Cool Fan Dry ...

Страница 17: ...ngs item 3 Press to select the air volume then press Confirm Air volume can be set in 5 stages Some models cannot be set in 5 stages The display is blank if the air volume is fixed More indicates a more powerful air volume The air conditioner is set to the selected air volume 2 3 Auto All Next Air Volume Settings item Auto All Next Auto All Next Return Confirm ...

Страница 18: ...play the Control screen of All Zone or Unit P 11 2 Press to select the Air Direction Settings item 3 Press to select the air direction then press Confirm Air direction can be set in 5 stages You can check the direction of the flap with the screen icon The selected air direction is set 2 3 Auto All Next Air Direction Settings item Auto All Next Auto All Next Return Confirm ...

Страница 19: ...Stops or Starts 1 Display the Control screen of All or Zone P 11 2 Press Control The Menu screen is displayed 3 Press to select Off Timer or On Timer then press Confirm The Off Timer or On Timer screen is displayed 4 Press to select the time then press Confirm If you choose Other you can set the timer for more than 2 hours 3 4 2 Control screen Auto All Next All Menu 1 2 1 Filter Sign Reset 2 Venti...

Страница 20: ...er of days and time then press Confirm The display returns to the Menu screen and Off Timer Running or On Timer Running is displayed Off Timer 0 day s 12 hour s later All Menu 1 2 1 Filter Sign Reset 2 Ventilation 3 Off Timer Running 4 On Timer 5 Energy saving operation ...

Страница 21: ...mer Running or On Timer Running then press Confirm The Off Timer or On Timer screen is displayed 3 Press Confirm The timer is cancelled and the Off Timer or On Timer screen is displayed 2 3 Auto All Next Off Timer Remaining time 15 minute s Cancel The remaining time until stop or start is displayed Off Timer 30 minute s 45 minute s 60 minute s 90 minute s Other ...

Страница 22: ...The Menu screen is displayed 3 Press to select Energy saving operation then press Confirm The Energy saving operation screen is displayed 4 Press to select the save rate then press Confirm The selected save rate is set Press Return to return to the Menu screen 2 3 4 All Control screen Auto All Next All Menu 1 2 1 Filter Sign Reset 2 Ventilation 3 Off Timer 4 On Timer 5 Energy saving operation Ener...

Страница 23: ...r Unit P 11 2 Press Control The Menu screen is displayed 3 Press to select Ventilation then press Confirm The Ventilation screen is displayed 4 Press to select ON OFF then press Confirm The ON OFF screen is displayed 5 Press to select ON or OFF then press Confirm Start or stop operation then press Return to return to Ventilation screen 3 4 5 2 Control screen Auto All Next All Menu 1 2 1 Filter Sig...

Страница 24: ...ose of the return air before supplying it We recommend you use this mode for cooling and heating in summer and winter Bypass Outdoor air is taken into a room as it is We recommend using this mode in the middle of spring and autumn To set Fan speed 2 Press to select Fan speed then press Confirm The Fan speed screen is displayed 3 Press to select the fan speed then press Confirm The selected fan spe...

Страница 25: ...REMENT After cleaning the filter be sure to perform Filter Sign Reset Other Features Cancel FILTER sign Filter Sign Reset 1 Display the Control screen of All Zone or Unit P 11 2 Press Control The Menu screen is displayed 3 Use to select Filter Sign Reset then press Confirm The Admin Password Entry screen is displayed 4 Enter the 4 digit password then press Confirm Press to select the digit and to ...

Страница 26: ...Confirm Press to select the digit and to select the number The Key lock screen is displayed 5 Press to select the item you wish to set then press Confirm The selected item is set Press Return to return to the Menu screen 3 4 5 2 Control screen Auto All Next All Menu 2 2 6 Key lock 7 Information Admin Password Entry 0 0 0 0 Key lock All allowed Centralized Control 1 Centralized Control 2 Centralize...

Страница 27: ... the operation Information 1 Display the Control screen of All Zone or Unit P 11 2 Press Control The Menu screen is displayed 3 Press to select Information then press Confirm The Information screen is displayed 4 Press Confirm The Model Information screen is displayed 3 4 2 Control screen Auto All Next All Menu 2 2 6 Key lock 7 Information Information 1 Model Information ...

Страница 28: ...oller Owner s Manual 28 EN NOTE Press Return to return to the Information screen Model Information The Remote Control Format and Software Version are displayed Model Information Name TCB SC643TLE Software Version xxxx xxx ...

Страница 29: ...operate the Central remote controller The function is not provided by the air conditioner There may be an error in the operation method Please check the operation explanation of the function This is because switching of Heat and Cool in the operation mode is prohibited It is not set even when operating the Central remote controller Problem Cause Solution The air conditioner does not operate even w...

Страница 30: ...z Consumed current 0 06 A Operating temperature and humidity ranges 0 40 C 10 90 no condensation Dimensions H 120 W 120 D 20 50 6 mm Weight 554 g Number of connected units Max 64 groups 64 units LCD Full dot liquid crystal with backlights Contact Output 2 Operation warning Input 2 All Run All Stop ...