Station Apparatus
Door Phone (MDFB)
Strata DK I&M 6/00
11-29
Station Apparatus
HDSS Console Configuration
The following considerations should be made when installing an HDSS console:
♦
A PEKU PCB is required.
♦
Two PEKU ports are required for the HDSS console (always circuits 7 and 8).
♦
The PESU does not support the HDSS console.
HDSS Programming
Program 03: Codes 23 and 24 identify the slot that supports a PEKU that interfaces with the HDSS
console.
Program 28: Assigns HDSS console to a telephone.
Program 29: Assigns individual button functions for the HDSS console.
Door Phone (MDFB)
This section provides installation instructions for the Door
Phone (MDFB). Door Phones can be installed can also with
Door Phone/Lock Control Units (see following section).
♦
DK14
can have up to 6 door phones
♦
DK40i
can have up to nine door phones
♦
DK424
and
DK424i
can have up to 12 door phones
Lock Control Unit and Door Phone
This section provides installation instructions for the Digital
(DDCB) or Electronic (HDCB) Door Phone/Lock Control
Units. Each DDCB or HDCB can support as many as three
MDFBs or two MDFBs and one door lock.
DDCBs or HDCBs can only connect to slot 11/port 004, slot 12/
port 012, slot 13/port 020 and slot 14/port 028. DDCBs can only
connect to circuit 5 (a PDKU or RDSU PCB and HDCBs can
connect only to circuit 5 of a PEKU or PESU PCB).
DDCBs and HDCBs cannot connect to the RSTU2, PSTU, or
KCDU.
1873
1874
Содержание Strata AirLink DK40i
Страница 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Страница 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Страница 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Страница 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Страница 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Страница 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Страница 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Страница 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Страница 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...