Program 25-1 Built-in AA Incoming Call Overflow Time
System & Station
Strata DK40 Programming Manual Spring 1999
3-47
Program 25-1
Built-in AA Incoming Call Overflow Time
Program Type:
System
Initialised Default:
20 seconds before overflow
Program 25-1 Overview
This program sets the time it takes an unanswered incoming Auto Attendant call to overflow
to a preassigned station(s). The time can be anywhere from 12 to 24 seconds—the default is
20 seconds. The overflow station or group of stations is assigned in
.
This overflow time applies to the overflow of incoming Auto Attendant calls to normal
Exchange line ringing if either a primary announcement device or K5RCU3 (DTMF) circuit
is not available.
Note
Auto Attendant will not answer when all of the K5RCU circuits or primary
announcements are busy.
(QWHU 3URJ 0RGH
0
6SNU
5 8
+ROG
0
6SNU
4
+ROG
0
6SNU
& &
+ROG
0
6SNU
& &
+ROG
SELECT = 1
AATT TIME = Seconds before overflowing
Enter the number of seconds, 12~24.