Toshiba RAV-SM1101DTP-A Скачать руководство пользователя страница 15

– 14 –

EN

ID

ID

 Under 70 dBA

RAV-SM1601DTP-A

42

11

Model

Sound power level (dBA)

Weight (kg)

Cooling

Heating

RAV-SM1101DTP-A

42

RAV-SM1401DTP-A

42

Specifications

10

Installation

Do not install the air conditioner in the following places

‡

Do not install the air conditioner in any place within 1 m from a TV, stereo, or radio set. If the unit is installed in 
such place, noise transmitted from the air conditioner affects the operation of these appliances.

‡

Do not install the air conditioner near a high frequency appliance (such as sewing machine or massager for 
business use), otherwise the air conditioner may malfunction.

‡

Places where iron or other metal dust is present. If iron or other metal dust adheres to or collects on the interior 
of the air conditioner, it may spontaneously combust and start a fire.

‡

Do not install the air conditioner in a humid or oily place, or in a place where steam, soot, or corrosive gas is 
generated.

‡

Do not install the air conditioner in a salty place such as seaside area.

‡

Do not install the air conditioner in a place where a great deal of machine oil is used.

‡

Do not install the air conditioner in a place where it is usually exposed to strong wind such as in seaside area.

‡

Do not install the air conditioner in a place where sulfureous gas generated such as in a spa.

‡

Do not install the air conditioner in a vessel or mobile crane.

‡

Do not install the air conditioner in an acidic or alkaline atmosphere (in a hot-spring area or near a chemicals 
factory, or in a place subject to combustion emissions). Corrosion may be generated on the aluminum fin and 
copper pipe of the heat exchanger.

‡

Do not install the air conditioner near an obstacle (such as air vent, lighting equipment) that disturbs discharge 
air. (Turbulent airflow may reduce the performance or disable devices.)

‡

Do not use the air conditioner for special purposes such as preserving food, precision instruments, or art objects, 
or where breeding animals or growing plants are kept. 
(This may degrade the quality of preserved materials.)

‡

Do not install the air conditioner over an object that must not get wet. (Condensation may drop from the indoor 
unit at a humidity of 80% or more or when the drain port is clogged.)

‡

Do not install the air conditioner in a place where an organic solvent is used.

‡

Do not install the air conditioner near a door or window subject to humid outside air. 
Condensation may form on the air conditioner.

‡

Do not install the air conditioner in a place where special spray is used frequently.

Be careful with noise or vibrations

‡

Do not install the air conditioner in a place where noise by outdoor unit or hot air from its air discharge annoys 
your neighbours.

‡

Install the air conditioner on a solid and stable foundation so that it prevents transmission of resonating, operation 
noise and vibration.

‡

If one indoor unit is operating, some sound may be audible from other indoor units that are not operating.

27-EN

28-EN

1116950231_EN.indd   14

1116950231_EN.indd   14

5/9/19   1:50 PM

5/9/19   1:50 PM

Содержание RAV-SM1101DTP-A

Страница 1: ...PLIT TYPE Owner s Manual Indoor Unit Model name Concealed Duct High Static Pressure Type English 1116950231 RAV SM1101DTP A RAV SM1401DTP A RAV SM1601DTP A 1116950231_EN indd cover1 1116950231_EN indd cover1 5 9 19 1 50 PM 5 9 19 1 50 PM ...

Страница 2: ...dren without supervision According to IEC 60335 1 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play wi...

Страница 3: ...o installs repairs maintains relocates and removes the air conditioners made by Toshiba Carrier Corporation He or she has been trained to install repair maintain relocate and remove the air conditioners made by Toshiba Carrier Corporation or alternatively he or she has been instructed in such operations by an individual or individuals who have been trained and is thus thoroughly acquainted with th...

Страница 4: ...ual WARNING General Carefully read Owner s Manual before starting the air conditioner There are many important things to keep in mind for daily operation Ask for installation to be performed by the dealer or a professional Only a qualified installer 1 is able to install an air conditioner If a non qualified person installs an air conditioner it may result in problems such as fire electric shock in...

Страница 5: ... the electrical control box cover of the indoor unit or service panel of the outdoor unit set the circuit breaker to the OFF position Failure to set the circuit breaker to the OFF position may result in electric shocks through contact with the interior parts Only a qualified installer 1 or qualified service person 1 is allowed to remove the electrical control box cover of the indoor unit or servic...

Страница 6: ...on 1 arrives Continuing to use the air conditioner in the trouble status may cause mechanical problems to escalate or result in electric shocks or other trouble If the fan guard is damaged do not approach the outdoor unit but set the circuit breaker to the OFF position and contact a qualified service person 1 to have the repairs done Do not set the circuit breaker to the ON position until the repa...

Страница 7: ... or any kind of liquid Do not wash the air conditioner Doing so may result in electric shock Check whether the installation base and other equipment have become deteriorated after being used for a long time Leaving them such condition may result in the unit s falling down and causing injury Do not leave flammable sprays or other flammable materials near the air conditioner and do not spray flammab...

Страница 8: ...EN Information on the transportation handling and storage of the carton Examples of indication on the carton Symbol Description Symbol Description Keep dry Do not drop Fragile Do not lay down Stacking height 6 cartons can be stacked in this case Do not walk on this carton This side up Do not step Handle with care Other cautions Description CAUTION Injury possibility Don t handle with packing band ...

Страница 9: ... TIMER SET TEST FILTER RESET TEMP CL FAN SAVE SWING FIX VENT MODE ON OFF UNIT LOUVER Display section Operation section 1 8 6 16 4 2 3 5 7 13 15 14 17 9 12 11 10 Auto High Med Low 11 UNIT No display The selected indoor unit number is displayed Also number of indoor or outdoor unit which an error occurs is displayed 12 Central control display Displayed when the air conditioner is used under the cent...

Страница 10: ...be sensed For details contact the dealer from which you have purchased the air conditioner 8 6 4 3 2 5 7 10 12 1 9 11 4 Correct usage When the air conditioner is used for the first time or when the setting is changed follow the steps below Settings are saved in memory and are displayed anytime the unit is turned on by pushing the button Preparation When the circuit breaker is turned on the partiti...

Страница 11: ... maintenance of the air conditioner 1 Set the displayed temperature to 18 C in the heating mode by pushing TEMP button 2 Set the displayed temperature to 8 C by pushing TEMP button for at least 4 seconds 1 Set the displayed temperature to 18 C by pushing TEMP button The air conditioner returns to the normal HEAT mode Select a desired temperature and operation mode 5 Timer operation Three timer mod...

Страница 12: ...ettings see To configure the power saving settings in Power saving mode Even when operation start stop operation mode change or power reset is performed during the power saving mode the power saving mode is retained until the next operation 7 Maintenance WARNING Cleaning the air filter and other parts of the air filter involves dangerous work in high places so be sure to have a qualified installer...

Страница 13: ...e circuit breaker and inform the dealer where you purchased the product of the product number and symptom Do not attempt to repair the unit by yourself as doing so is dangerous If the check indicator e g is displayed on the remote controller LCD inform the dealer of its content as well If any of the following occur stop running the unit immediately turn off the circuit breaker and contact the deal...

Страница 14: ...defrosting operation During the defrosting operation the defrosted water will be drained from the bottom plate of the outdoor unit Heating capacity In the heating operation the heat is absorbed from the outside and brought into the room This way of heating is called heat pump system When the outside temperature is too low it is recommended to use another heating apparatus in combination with the a...

Страница 15: ...in an acidic or alkaline atmosphere in a hot spring area or near a chemicals factory or in a place subject to combustion emissions Corrosion may be generated on the aluminum fin and copper pipe of the heat exchanger Do not install the air conditioner near an obstacle such as air vent lighting equipment that disturbs discharge air Turbulent airflow may reduce the performance or disable devices Do n...

Страница 16: ... 15 MEMO 1116950231_EN indd 15 1116950231_EN indd 15 5 9 19 1 50 PM 5 9 19 1 50 PM ...

Страница 17: ... 16 EN ID ID MEMO 1116950231_EN indd 16 1116950231_EN indd 16 5 9 19 1 50 PM 5 9 19 1 50 PM ...

Страница 18: ... 17 MEMO 1116950231_EN indd 17 1116950231_EN indd 17 5 9 19 1 50 PM 5 9 19 1 50 PM ...

Страница 19: ...1116950231_EN indd 18 1116950231_EN indd 18 5 9 19 1 50 PM 5 9 19 1 50 PM ...

Страница 20: ...144 9 Moo 5 Bangkadi Industrial Park Tivanon Road Tambol Bangkadi Amphur Muang Pathumthani 12000 Thailand 1116950231 1116950231_EN indd 19 1116950231_EN indd 19 5 9 19 1 50 PM 5 9 19 1 50 PM ...

Отзывы: