6
INSTALLATION DIAGRAM OF INDOOR UNIT
INSTALLATION DIAGRAM OF INDOOR UNIT
Part
code
Parts name
Q’ty
A
Refrigerant piping
Liquid side : Ø6.35 mm
Gas side
: Ø9.52 mm
One
each
B
Pipe insulating material
(polyethylene foam, 6 mm thick)
1
C
Putty, PVC tapes
One
each
Optional Installation Parts
2
3
The auxiliary piping can be connected to
the left, rear left, rear right, right, bottom
right or bottom left.
Right
Rear
right
Bottom
right
Rear
left
Bottom left
Left
Insulate the refrigerant pipes separately
with insulation, not together.
6 mm thick heat resisting
polyethylene foam
1
Batteries
7
Flat head
wood screw
4
Remote control
holder
Wireless remote control
Shield pipe
(Attach to the front panel.)
Air
fi
lter
Hook
Installation
plate
Hook
65 mm or more
300 mm or more
300 mm or more
Insert the cushion between the indoor
unit and wall, and tilt the indoor unit for
better operation.
For the rear left and left piping
Wall
Make sure to run the drain hose sloped
downward.
Do not allow the drain hose to get slack.
Cut the piping
hole sloped
slightly.
The
fl
are connection should be installed
outdoors.
The provided Remote Controller is a wireless
type, which also can be used as a wire.
Please see “How to Connect The Remote
Controller for Wired Operation”, in case of
wired control is required.
5
Filter
!
Flat head
wood screw
7
Flat head
wood screw
"
Battery
cover
Refrigerant piping
must be protected from
physical damage.
Install a plastic cover or
equivalent.