Red
White
Black
Red
White
Black
11-8.
Outdoor Unit
No.
1
2
3
5
Part name
Compressor
2M
21, 3M41
: D
X
136
A
1
T-
4
0
N
3M
31
: DX151A1T-30N
Outdoor fan motor
(Model :
ICF-340-A70-1
)
Compressor thermo. Bimetal type
(Model : CS-12AL)
Outdoor temperature sensor (TO),
pipe temperature sensor
(TGa, TGb, TGc),
discharge temperature sensor (TD)
.
Checking procedure
Measure the resistance value of each winding by using the tester.
at
20°C
Measure the resistance value of winding by using the tester.
Check conduction by using the tester.
Disconnect the connector, and measure resistance value with the tester.
(Normal temperature)
Position
Red - White
White - Black
Black - Red
Resistance value
18.80
±
2
Ω
Temperature
Sensor
TD (k
Ω
)
TO
(k
Ω
)
TGa to TG
c
(k
Ω
)
10°C
20°C
25°C
40°C
50°C
105
64
51
27
18
20.6
12.6
10.0
5.1
3.4
20.0
12.5
10.0
5.3
3.6
4
High pressure switch
(Model :
ACB-1UB177W
)
Check conduction by using the tester.
100
30
40
50
60
70
80
90
20
10
0
0
10
20
30
40
50
Resistance value (k
Ω
)
Temperature (˚C)
TD
TO
: Discharge temp. sensor
: Outdoor temp. sensor
TGa to TG
c
: Gas side temp. sensor
TO, TGa to TG
c
TD
[1] Sensor characteristic table
11-
7
. Inspection of the Main Parts
Position
Resistance value
DX136A1T-40N
DX151A1T-30N
Red - White
White - Black
Black - Red
1.31
Ω
1.1
Ω
at
20°C
- 77 -