Turn on the circuit breaker
Initial status
D800
D801
D802
D803
D804
D805
:ON
:OFF
Push SW01 for
5 sec or more
Setting mode of various functions
D800
D801
D802
D803
D804
D805
¯
:ON
:OFF
¯
:Slow Flashing (1 time/sec)
Push SW01
8 times
Power Save setting mode(Limit/No limit).
D800
D801
D802
D803
D804
D805
:ON
:OFF :Rapid Flashing (5 times/sec)
D805 represents to the limit/No limit.
D805
:No limit,
:Limit (Factory setting : No limit)
Push SW02
1 time
Power Save setting change (No limit
→
Limit)
D800
D801
D802
D803
D804
D805
:ON
:OFF :Rapid Flashing (5 times/sec)
Push SW02 for
5 sec or more
Power Save setting completion
D800
D801
D802
D803
D804
D805
¯
:ON
:OFF
¯
:Slow Flashing (1 time/sec)
Push SW01
2 times
Current Limit setting mode(11A/8.5A)
D800
D801
D802
D803
D804
D805
:ON
:OFF :Rapid Flashing (5 times/sec)
D805 represents to the 11A/8.5A.
D805
:11A,
:8.5A (Factory setting : 11A)
*Go to
1
in the case of 11A setting
Push SW02
1 time
Current Limit setting change (11A
→
8.5A)
D800
D801
D802
D803
D804
D805
:ON
:OFF :Rapid Flashing (5 times/sec)
Push SW02 for
5 sec or more
Current Limit setting completion
D800
D801
D802
D803
D804
D805
¯
:ON
:OFF
¯
:Slow Flashing (1 time/sec)
1
Push SW01 and SW02
for 5 sec or more
Function setting completion (return to the initial status)
D800
D801
D802
D803
D804
D805
:ON
:OFF
<Cancellation method of Power Save setting >
Initial status
D800
D801
D802
D803
D804
D805
:ON
:OFF
Push SW01 for
5 sec or more
Setting mode of various functions
D800
D801
D802
D803
D804
D805
¯
:ON
:OFF
¯
:Slow Flashing (1 time/sec)
Push SW01
8 times
Power Save setting mode(Limit/No limit).
D800
D801
D802
D803
D804
D805
:ON
:OFF :Rapid Flashing (5 times/sec)
D805 represents to the limit/No limit.
D805
:No limit,
:Limit (Factory setting : No limit)
Push SW02
1 time
Power Save setting change (Limit
→
No limit)
D800
D801
D802
D803
D804
D805
:ON
:OFF :Rapid Flashing (5 times/sec)
Push SW02 for
5 sec or more
Power Save setting completion
D800
D801
D802
D803
D804
D805
¯
:ON
:OFF
¯
:Slow Flashing (1 time/sec)
Push SW01 and SW02
for 5 sec or more
Function setting completion (return to the initial status)
D800
D801
D802
D803
D804
D805
:ON
:OFF
Notice
• If an unknown point generated on the way of the operation, push and hold
SW01 and SW02 for 5 seconds or more simultaneously.
You can return to the initial status.
Important instruction
To all installers
Please be remin
d
ed that all air conditioners installed at HDB
fl
ats are subjected to a current restriction of 11A or 8.5A.
It is the installer’s responsibility to have to current release control set correctly for the type of HDB
fl
at which the IMS unit is installed.
The setting method is the following.
For details refer also to the service manual.