CAUTION
• Incorrect/incomplete wiring will cause
electrical
fi
res or smoke.
• Prepare the power source for exclusive
use with the air conditioner.
• This product can be connected to the main
power.
Fixed wire connections:
A switch that disconnects all poles and
has a contact separation of at least 3 mm
must be incorporated into the
fi
xed wiring.
■
Wire Connection
• Connect the indoor/outdoor connecting cables to the identical terminal
numbers on the terminal block of each unit.
• Incorrect connection may cause a failure.
1. Remove the valve cover screws.
2. Pull the valve cover in the direction of arrow, and remove it.
3. Remove the cord clamp and the terminal cover.
Valve cover
Terminal cover
Cord clamp
4. Connect the wires for the power source and each indoor unit.
• Connect the connecting cable to the terminal as identi
fi
ed by the
matching numbers on the terminal block of the indoor and the outdoor
unit.
5. Fix the wiring connections for the power source and each indoor unit
securely using a cord clamp.
6. Attach the terminal cover and the valve cover.
Stripping Length of connecting cable for outdoor unit
• The dash lines show on-site wiring.
(System
interconnection wires)
1
2
L
N
3
1
2
3
Input power
Leakage
breaker
Indoor unit
Remote
controller
Earth
(Main circuit)
Model
RAS-2M21U2ACVG-SG
RAS-3M31U2ACVG-SG,
RAS-3M41U2ACVG-SG
Power supply
1ph, 50Hz, 220-240V
Maximum running
current
11.2A
11.5A
Circuit breaker
rating
15A
(All types can be used)
Power cord
H07RN-F or 60245 IEC 66
3-core
2
.5 mm²
Connecting
cable
H07RN-F or 60245 IEC 66
4-core 1.5 mm²
Earth screw
Earth screw
Earth wire
Earth wire
5
5
5
1 2 3
L N
5
55
55
30
30
Earth screw
Earth screw
Connecting cable
Unit C
Connecting cable
Unit A
Connecting cable
Unit B
Power cord
Power cord
Connecting cable
- 53 -