11-12
'50RSHUDWLRQ$61=6
'5&%RDUG/D\RXW
COM-DRM1 (Demand Response Mode 1)
Operation in this mode is compressor off
COM-DRM2 (Demand Response Mode 2)
Operation in this mode is the air conditioner continues to cool or heat, by the electrical energy consumed is
not more than 50% of the total electrical energy.
COM-DRM3 (Demand Response Mode 3)
Operation in this mode is the air conditioner continues to cool or heat, by the electrical
H
nergy comsumed is
&RQQHFWLQJ0RGH
not more than 75% of the total electrical energy.
DRC operation will concern with current release
DRM
Cooling
Heating
DRM 1
Compressor stop
Compressor stop
DRM 2
2.5
A
2.4
A
DRM 3
3.8
A
3.2
A
GND
+12V
RAS-2M18S3AV-A
- 9
9
-