POWER-SELECTION AND SILENT
OPERATION (OUTDOOR UNIT)
Power-Selection (
)
This function is used when the circuit breaker is shared with other electrical appliances. It limits the maximum current
and power consumption to 100%, 75%, or 50% and can be implemented by POWER-SELECTION. The lower
percentage, the higher saving and also longer compressor lifetime.
Silent Operation (
)
Keep outdoor unit operating silently to ensure either yourself or neighborhood will have a tight sleep in nighttime.
By this feature, the heating capacity will be optimized to deliver such silent experience.
The silent operation can be selected from one of two purposes (Silent 1 and Silent 2).
There are three setting parameters: Standard level > Silent 1 > Silent 2
Silent 1:
Though operating silently, the Heating (or Cooling) capacity is still prioritized to ensure having suf
fi
cient comfort inside
the room.
This setting is a perfect balance between the Heating (or Cooling) capacity and the Sound level of outdoor unit.
Silent 2:
Compromising the Heating (or Cooling) capacity to the Sound level in any circumstance where the outdoor unit’s
sound level is highly prioritized.
This setting has a purpose to reduce the maximum sound level of outdoor unit by 4 dB(A).
SILENT#2
SILENT#1
Power-Selection and Silent Operation (Outdoor Unit)
l
When the level is selected, POWER-SEL level
fl
ashes on remote LCD display for 3 seconds.
In case of 75% and 50% level, number “75” or “50” also
fl
ashes for 2 seconds.
l
Due to the reason that POWER-SELECTION function limits the maximum current, inadequate cooling or
heating capacity may occur.
Notes
l
While activating of Silent operation, inadequate heating (or cooling) capacity may occur.
Notes
[100%]
[75%]
[50%]