
Item
7
. Louver control
1) Louver
position
Operation flow and applicable data, etc.
This function controls the air direction of the indoor unit.
Description
•
The position is automatically controlled according to the operation
•
The set louver position is stored in memory by the microcomputer,
The angle of the louver is indicated as the louver closes fully is 0°.
mode (COOL/HEAT).
and the louver returns to the stored position when the next operation
is performed. (Cooling/Heating memory position)
1) Louver position in cooling operation
Manual and automatic operation
HI-POWER operation
Initial setting is directs downward (13.4°)
Default setting is directs downward (26.1°)
Wide air direction
Wide position is directs downward (13.4°)
Wide-angle
Right wide
Left wide
Left side lover setting is left facing (45.9°)
Right side lover setting is right facing (45.9°)
Left side lover setting is front facing (0°)
Right side lover setting is right facing (45.9°)
Left side lover setting is left facing (45.9°)
Right side lover setting is front facing (0°)
Spot air direction
Spot position is directs downward (43.1°)
Wide front
Sport right
Spot left
Left side lover setting is front facing (0°)
Right side lover setting is front facing (0°)
Left side lover setting is right facing (45.9°)
Right side lover setting is right facing (45.9°)
Left side lover setting is left facing (45.9°)
Right side lover setting is left facing (45.9°)
FILE NO. SVM-15058
- 34 -
Содержание RAS-18G2ACVP-T
Страница 18: ...5 WIRING DIAGRAM FILE NO SVM 15058 18 ...
Страница 122: ......