No.
Replacement part name
Work procedure
Remarks
9
Electronic expansion
valve coil
1. Detachment
1) Perform step 1 in
2
, all the steps in
3
and
1 in
5
.
2) Remove the coil by pulling it up from the
electronic control valve body.
2. Attachment
1) When assembling the coil into the valve
body, ensure that the coil anti-turn lock is
installed properly in the pipe.
<Handling precaution>
When handling the parts, do not pull the leads.
When removing the coil from the valve body, use
your hand to secure the body in order to prevent
the pipe from being bent out of shape.
!
Fan Guard
1. Detachment
1) Perform work of item 1 of
2
.
2) Remove the front cabinet, and put it down
so that fan guard side directs downward.
Perform work on a corrugated cardboard,
cloth, etc. to prevent fl aw to the product.
3) Remove the hooking claws by pushing
minus screwdriver according to the arrow
mark in the right figure, and remove the fan
guard.
2. Attachment
1) Insert claws of the fan guard in the holes of
the front cabinet.
Push the hooking claws (9 positions) by
hands and fix the claws.
All the attaching works have completed.
Check that all the hooking claws are fi xed
to the specifi ed positions.
Coil inserting
position
Coil anti-turn
lock position
Coil
anti-turn
lock
Minus screwdriver
Hooking claw
FILE NO. SVM-15058