– 34 –
FILE NO. SVM-02001
8-3. Installation
8-3-1. Optional Installation Parts
Air inlet
Drain outlet
Fig. 8-3-1
<Fixing bolt arrangement of outdoor unit>
RAS-07UAH-E, RAS-07UA-E, RAS-07UAX-1
Part
Code
A
B
C
Q'ty
one
Each
1
one
Each
Parts name
Refrigerant piping
Liquid side :
∅
6.35 mm
Gas side
:
∅
9.52 mm (RAS-07UK,
RAS-10UK)
:
∅
12.70 mm (RAS-13UK)
Pipe insulating material
(polyethylene foam, 6 mm thick)
Putty, PVC tapes
Air outlet
RAS-13UAH-E, RAS-13UA-E, RAS-13UAX
600 mm
325 mm
52.5 mm
120 mm
Air inlet
Drain outlet
RAS-10UAH-E, RAS-10UA-E, RAS-10UAX-1
Air outlet
Fig. 8-3-2
600 mm
111 mm
30 mm
230 mm
Fig. 8-3-3
Air outlet
Drain outlet
Air inlet
•
Secure the outdoor unit with fixing bolts and nuts if the unit is likely to be exposed to a strong wind.
•
Use
∅
8 mm or
∅
10 mm anchor bolts and nuts.
•
If it is necessary to drain the defrost water, attach
9
drain nipple to the bottom plate of the outdoor unit
before installing it.
500 mm
97 mm
60 mm