FILE NO. SVM-12029
1
Room temp. (TA) sensor
Heat exchanger (TC) sensor
2
Remote control
3
Louver motor
MP24ZCT
4
Indoor fan motor
Disconnect the connector and measure the resistance value with tester.
(Normal temp.)
Refer to 11-5-1 (5)
Measure the resistance value of each winding coil by using the tester.
(Under normal temp. 25°C)
Refer to 11-5-1 (3) and (4).
11-8-3
. Indoor unit (Other parts)
No.
Part name
Checking procedure
11-8-4
. Outdoor unit
Sensor
TA, TC (k
Ω
)
20.7
12.6
10.0
7.9
4.5
5
4
3
2
1
White
Yellow
Yellow
Yellow
Yellow
5
4
3
2
1
Position
Resistance value
1 to 2
1 to 3
250±20
Ω
1 to 4
1 to 5
Temperature
10°C 20°C 25°C 30°C 40°C
No.
1
Part name
Compressor
(Model : DA89X1C-23EZ)
Checking procedure
Red
White
Black
Measure the resistance value of each winding by using the tester.
Position
Red - White
White - Black
Black - Red
Resistance value
Under 20ºC
1.1
Ω
2
Outdoor fan motor
(Model : WLF-240-20A-1)
3
Measure the resistance value of winding by using the tester.
N
Red
White
C1.5 mF
450V
Black
Position
Resistance value
White - Black
Black - Red
260.1
235.2
Outdoor temperature sensor
(TO), discharge temperature
sensor (TD), suction temperature
exchanger temperature sensor
(TE)
Disconnect the connector, and measure resistance value with the tester.
(Normal temperature)
TGa : Heat pump model only.
TO, TS, TE : Refer to the TA, TC characteristic table in Indoor
(Refer to Table 1
1
-8-3, No.1).
Temperature
10°C
20°C
30°C
40°C
50°C
Sensor
TA, TC (k
Ω
) 105 64 41 27 18