46
P9 ASD Installation and Opeation Manual
Feedback (Inst)
— Provides a status of the
Real Time Feedback
in Hz.
Feedback (1 Second)
— Provides a status of the
1-Second Averaging
feedback in Hz.
Torque
—
Displays the
Output Torque
as a percentage of the rated capacity of the P9 ASD.
Torque Reference
—
Displays the
Torque Reference
as a percentage of the maximum torque
available.
Torque Current
—
Displays the torque-producing current value.
Excitation Current
—
Displays the current value required to produce the excitation field.
PID Feedback
— Provides a status of the
PID
Real Time Feedback
in Hz.
Input Power
— Displays the
Input Power
in Kilowatts (kW).
Output Power
— Displays the
Output Power
in Kilowatts (kW).
Pattern Group Number
—
Displays the active
Pattern Run Group Number
.
Pattern Group Cycle
—
Displays the cycle number of the active
Pattern Run Group
.
Pattern Group Preset
—
Displays the active
Preset Speed
being run of the active
Pattern Run
Group
.
Pattern Time
—
Displays the remaining time for the active
Pattern Run Group
.
RR
— Displays the
RR
input value as a percentage of the full range of the
RR
value (potentiometer
input).
V/I
— Displays the
V/I
input setting as a percentage of the full range of the
V/I
value.
Note:
The isolated
V/I
input terminal may receive
Current
or
Voltage
to control the
output speed or the output torque. The input signal type must be selected at
SW301
on the
Terminal Board
.
The
V
input setting of
SW301
is used for the 0 – 10 VDC analog input signal and
the
I
input setting of
SW301
is used for the 0 – 20 mA analog input signal. Either
may be used as a frequency or torque command source. See parameter
F201
for
more information on the setup of this terminal.
RX
— Displays the
RX
input setting as a percentage of the full range of the
RX
value (-10 to +10
VDC input).
RX2 Option (AI1)
— Displays the
RX2
input setting as a percentage of the full range of the
RX2
value.
Note:
The RX2 function is available on the
Expansion IO Card Option 1
option board
(P/N ETB003Z) only.
Trip Code
—
Displays
None
if there are no errors, or displays one of the associated
Fault Codes
if
there is an active
Fault
(e.g.,
E
=
Emergency Off
).
Past Trip 1
—
This function records and displays the last trip incurred. Subsequent trips will replace
Past Trip 1
. As trip records are replaced, they are shifted to the next level of the
Past Trip
locations
until being deleted (i.e.,
Past Trip 1
is moved to
Past Trip 2
and then to
Past Trip 3
until being
shifted out of
Past Trip 4
). Once shifted out of
Past Trip 4
, the record is deleted. If no trips have
occurred since the last reset,
No Error
is displayed for each trip record.
Past Trip 2
—
Past trip information or
None
.
ast Trip 1
Содержание P9
Страница 1: ...TM P9 ASD Install Op Manual TOSHIBA P9 ASD INSTALLATION OPERATION MANUAL DN 64054 004 February 2013 ...
Страница 2: ......
Страница 3: ...Document Number 64054 004 February 2013 P9 ASD Installation Operation Manual TM ...
Страница 4: ......
Страница 280: ...270 P9 ASD Installation and Operation Manual Figure 38 See Tables 17 and 18 for Actual Dimensions ...
Страница 281: ...P9 ASD Installation and Operation Manual 271 Figure 39 See Tables 17 and 18 for Actual Dimensions ...
Страница 282: ...272 P9 ASD Installation and Operation Manual Figure 40 See Tables 17 and 18 for Actual Dimensions ...
Страница 285: ...P9 ASD Installation and Operation Manual 275 Figure 43 See Table 18 for the associated device Dimensions are in in cm ...
Страница 304: ...294 P9 ASD Installation and Operation Manual W W T3 16 Warranty Card 2 W Phase Over Current 265 ...
Страница 305: ......