12
P9 ASD Installation and Operation Manual
Load-Produced Negative Torque
When the
P9 ASD
is used with a load that produces negative torque (an overhauling load), the over-
voltage or over-current protective functions of the P9 ASD may cause nuisance tripping.
To minimize the undesirable effects of negative torque, the dynamic braking system may be used. The
dynamic braking system converts the regenerated energy into heat that is dissipated using a braking
resistor. The braking resistor must be suitably matched to the load. Dynamic braking is very effective in
reducing the DC bus voltage during a momentary over-voltage condition.
If the dynamic braking system or a component of this system were to fail under extreme conditions, the
dynamic braking resistor may experience an extended over-current condition. The DBR circuit was
designed to dissipate excessive amounts of heat and if the extended over-current condition were allowed
to exceed the circuit parameters, this condition could result in a fire hazard.
To combat this condition, the 3-phase input may be connected using contactors that are configured to open
in the event of an extended DBR over-current condition or an internal circuit failure. Using a thermal
sensor and/or overload protection as the 3-phase input contactor drive signal, the contactors will open and
remove the 3-phase input power in the event of an extended DBR over-current or system over-voltage
condition. See
Dynamic Braking Protection on pg. 280
for more information on using dynamic braking
with the P9 ASD.
Motor Braking
The motor may continue to rotate and coast to a stop after being shut off due to the inertia of the load. If an
immediate stop is required, a braking system should be used. The two most common types of motor
braking systems used with the
P9 ASD
are
DC Injection Braking
and
Dynamic Braking
.
For further information on braking systems, see
DC Injection Braking on pg. 125
and
.
CAUTION
Содержание P9
Страница 1: ...TM P9 ASD Install Op Manual TOSHIBA P9 ASD INSTALLATION OPERATION MANUAL DN 64054 004 February 2013 ...
Страница 2: ......
Страница 3: ...Document Number 64054 004 February 2013 P9 ASD Installation Operation Manual TM ...
Страница 4: ......
Страница 280: ...270 P9 ASD Installation and Operation Manual Figure 38 See Tables 17 and 18 for Actual Dimensions ...
Страница 281: ...P9 ASD Installation and Operation Manual 271 Figure 39 See Tables 17 and 18 for Actual Dimensions ...
Страница 282: ...272 P9 ASD Installation and Operation Manual Figure 40 See Tables 17 and 18 for Actual Dimensions ...
Страница 285: ...P9 ASD Installation and Operation Manual 275 Figure 43 See Table 18 for the associated device Dimensions are in in cm ...
Страница 304: ...294 P9 ASD Installation and Operation Manual W W T3 16 Warranty Card 2 W Phase Over Current 265 ...
Страница 305: ......