background image

VRF model

Digital Inverter / Super Digital Inverter

MMU-AP0091H, AP0121H

RAV-SM560UT-E

MMU-AP0151H, AP0181H

RAV-SM800UT-E

MMU-AP0241H, AP0271H

RAV-SM1100UT-E

MMU-AP0301H, AP0361H

RAV-SP1100UT-E

MMU-AP0481H, AP0561H

RAV-SM1400UT-E

Accessories for

4-Way Air Discharge Cassette Type

Design Guide

Jan. 2005

Indoor unit

(Design sample)

 
 
 

 
 

Accesory parts list

1.

2. Combination pattern
3. Super long life filter

TCB-LF1601UE

4. High efficiency filter

TCB-UFM1601UE / UFH1601UE

5. Fresh air and filter chamber

TCB-GFC1601UE

6. Fresh air inlet box

TCB-GB1601UE

7.

8.

Fresh air intake (Design guide)

Auxiliary fresh air flange

9.

10.

TCB-FF101URE

Spacer for hight direction kit

TCB-SP1601UE

Air dischage direction kit

TCB-BC1601UE

11. Branchind duct

Содержание MMU-AP0091H

Страница 1: ...rge Cassette Type Design Guide Jan 2005 Indoor unit Design sample Accesory parts list 1 2 Combination pattern 3 Super long life filter TCB LF1601UE 4 High efficiency filter TCB UFM1601UE UFH1601UE 5 Fresh air and filter chamber TCB GFC1601UE 6 Fresh air inlet box TCB GB1601UE 7 8 Fresh air intake Design guide Auxiliary fresh air flange 9 10 TCB FF101URE Spacer for hight direction kit TCB SP1601UE ...

Страница 2: ...sh Air and Filter Chamber TCB GFC1601UE For fresh air intake and installing high efficiency filter or super long life filter Fresh Air Inlet Box TCB GB1601UE Use with TCB GFC1601UE Auxiliary Fresh Air Flange TCB FF101URE Easy fresh air intake by using the knockout hole of indoor unit dia 100mm Spacer for Height Adjustment TCB SP1601UE Height 50mm Air Discharge Direction kit TCB BC1601UE Air direct...

Страница 3: ...sed as filter frame Parts Fresh air inlet box TCB GB1601UE Fresh air and filter chamber TCB GFC1601UE Super long life fitler TCB LF1601UE High efficiency filter 65 TCB UFM1601UE High efficiency filter 90 TCB UFH1601UE Spacer for height adjustment TCB SP1601UE Air discharge direction kit TCB BC1601UE 1 Setup of air volume by connecting main wired remote controller and item code setting is necessary...

Страница 4: ...used with the standard filter packed with the ceiling panel RBC U21PG W E 3 Change procedure for DC fan tap is necessary when super long life filter is used a Setting by main wired remote controller Item code 5d At shipment Super long life filter b Setting by wireless remote controller W E Dip Switch S003 Tap 1 Tap 2 At shipment off off Super long life filter off on c Setting by short plug on indo...

Страница 5: ...ller Item code 5d At shipment High efficiency filter b Setting by wireless remote controller TCB AX21U W E Dip Switch S003 Tap 1 Tap 2 At shipment off off High efficiency filter on off c Setting by short plug on indoor P C board Short plug status At shipment Super long life filter Dimension Side frame Filter material Seal material Air flow label CN 112 CN 110 Setting data 0000 0003 PIN No TCB UFM ...

Страница 6: ...filter or super long life filter shall be installed to the filter chamber and these filter are placed between the indoor unit and the ceiling panel The high efficiency filter can not be reproduced Periodical replacement is necessary Fresh air and filter chamber Applicable filter Applicable model super long life filter TCB LF1601UE model name size A high efficiency filter 65 TCB UFM1601UE MMU AP009...

Страница 7: ...ed with the fresh air and filter chamber 6 Fresh air inlet box TCB GB1601UE dimension installation accessories 6 215 275 35 121 114 95 77 190 312 A 950 950 216 O97 O 1 2 3 65 22 90 11 144 77 95 194 35 45 108 98 150 Flesh Air Bottom face of ceiling Drain Port inlet box Flesh air and filter chamber Sold separately Refrigerant pipe Gas side Refrigerant pipe Liquid side ...

Страница 8: ...t sucking dust 6 Be sure to insulate the fresh air duct In order to accelate starting up in heating mode implement pre heating operation by cutting off fresh air intake Up to 20 fresh air intake ratio is available by using the booster fan fresh air intake ratio fresh air volume total air volume X 100 Inter lock circuit 1 Connect the driving relay of the duct fan DC 12 V between 1 and 6 on the indo...

Страница 9: ...cer to prevent the effect of noise 2 A gap between the styrol and steel plate may cause a trouble such as dew drop to occur Be sure to first attach accessory heat insulator A with it aligned to the screw hole then attach B according to the figure below 3 Install auxiliary fresh air flange to the indoor unit main body with accessory 4 fixing screws Fixing hole of indoor unit Indoor unit Check port ...

Страница 10: ... name material color TCB SP1601UE styrene foam moon white 9 Specer for height adj ustment TCB SP1601UE The height of this specer up to 50 mm Installation is available in the narrow space above the ceiling 9 ...

Страница 11: ...y of Indoor unit 3 Way Air Discharge 2 Way Air Discharge In case connecting Branching Duct Branching duct Branching duct Discharge direction Drain pipe Ref pipe Cover A 1 Packing A Cover B Cut off packing B by 50mm Cover Packig B Cover C Packing B Upper side Cover A 1 Packing A Lower side Cover C Packing B Cover B Cut off packing B by 50mm Upper side Cover A 1 Packing A Lower side Cover C Packing ...

Страница 12: ...09 to 015 type Digital Inverter and Super Digital Inverter Dimension Air volume m3 h Static Pressure Pa Knockout square for branching duct in indoor unit Install the cover Use air discharge derection kit TCB BC1601UE to cover the air discharge port Design sample of branching duct flange Installation sample Characteristics between air volume of branching duct and static pressure Cover method 11 duc...

Отзывы: