39
Check code
Main
remote
controller
display
F01
F02
F03
F04
F05
F06
F07
F08
F10
F12
F13
F15
F16
F23
F24
F29
F31
H01
H02
H03
H04
H06
H07
H08
H14
H16
L03
L04
L05
L06
L07
L08
L09
L10
L20
L28
L29
L30
—
Outdoor 7-segment display
Auxiliary code
—
—
—
—
—
—
F04
—
F05
—
F06
—
F07
—
F08
—
—
—
F12
—
F13
01: Comp. 1 sid
02: Comp. 2 side
F15
—
F16
—
F23
—
F24
—
—
—
F31
—
H01
01: Comp. 1 side
02: Comp. 2 side
01: Comp. 1 side
H02
02: Comp. 2 side
H03
01: Comp. 1 side
02: Comp. 2 side
H04
—
H06
—
H07
—
01: TK1 sensor error
H08
02: TK2 sensor error
03: TK3 sensor error
04: TK4 sensor error
H14
—
01: TK1 oil circuit system error
H16
02: TK2 oil circuit system error
03: TK3 oil circuit system error
04: TK4 oil circuit system error
—
—
L04
—
—
—
L06
No. of indoor units with priority
—
—
L08
—
—
—
L10
—
L20
—
L28
—
01: IPDU1 error
02: IPDU2 error
03: IPDU3 error
L29
04: Fan IPDU error
05: IPDU1 + Fan IPDU error
06: IPDU2 + Fan IPDU error
07: All IPDU error
L30
Detected indoor address
L31
—
Wireless remote controller
Sensor block display
of receiving unit
Operation
Timer
PRE, DEF.
Flash
¤
¤
l
ALT
¤
¤
l
ALT
¤
¤
l
ALT
¤
¤
¡
ALT
¤
¤
¡
ALT
¤
¤
¡
ALT
¤
¤
¡
ALT
¤
¤
¡
ALT
¤
¤
l
ALT
¤
¤
¡
ALT
¤
¤
¡
ALT
¤
¤
¡
ALT
¤
¤
¡
ALT
¤
¤
¡
ALT
¤
¤
¡
ALT
¤
¤
l
SIM
¤
¤
¡
SIM
l
¤
l
l
¤
l
l
¤
l
l
¤
l
l
¤
l
l
¤
l
l
¤
l
l
¤
l
l
¤
l
¤
l
¤
SIM
¤
¡
¤
SIM
¤
l
¤
SIM
¤
l
¤
SIM
¤
l
¤
SIM
¤
l
¤
SIM
¤
l
¤
SIM
¤
¡
¤
SIM
¤
¡
¤
SIM
¤
¡
¤
SIM
¤
¡
¤
SIM
¤
¡
¤
SIM
—
Check code name
Indoor TCJ sensor error
Indoor TC2 sensor error
Indoor TC1 sensor error
TD1 sensor error
TD2 sensor error
TE1 sensor error
TL sensor error
TO sensor error
Indoor TA sensor error
TS1 sensor error
TH sensor error
Outdoor temp. sensor miscabling (TE, TL)
Outdoor pressure sensor miscabling (Pd, Ps)
Ps sensor error
Pd sensor error
Indoor other error
Indoor EEPROM error
Compressor break down
Magnet switch error
Overcurrent relay operation
Compressor trouble (lock)
Current detect circuit system error
Comp 1 case thermo operation
Low pressure protective operation
Oil level down detective protection
Oil level detective temp sensor error
Comp 2 case thermo operation
Oil level detective circuit error
Magnet switch error
Overcurrent relay operation
Indoor center unit duplicated
Outdoor line address duplicated
Duplicated indoor units with priority
(Displayed in indoor unit with priority)
Duplicated indoor units with priority
(Displayed in unit other than indoor unit with priority)
Group line in individual indoor unit
Indoor group/Address unset
Indoor capacity unset
Outdoor capacity unset
Duplicated central control addresses
Over No. of connected outdoor units
No. of IPDU error
Indoor outside interlock
Extended I/C error
Judging device
Indoor
Indoor
Indoor
I/F
I/F
I/F
I/F
I/F
Indoor
I/F
IPDU
I/F
I/F
I/F
I/F
Indoor
I/F
IPDU
MG-SW
Overcurrent relay
IPDU
IPDU
I/F
I/F
I/F
I/F
I/F
I/F
MG-SW
Overcurrent relay
Indoor
I/F
I/F
I/F
Indoor
Indoor, I/F
Indoor
I/F
Indoor
I/F
I/F
Indoor
I/F
Check code
Main
remote
controller
display
P01
P03
P04
P05
P07
P10
P12
P13
P15
P17
P19
P20
P22
P26
P29
P31
Outdoor 7-segment display
Auxiliary code
—
—
P03
—
P04
01: Comp. 1 side
02: Comp. 2 side
P05
01: Phase-missing detection
02: Phase error
P07
01: Comp. 1 side
02: Comp. 2 side
P10
Detected indoor address
—
—
P13
—
P15
01: TS condition
02: TD condition
P17
—
P19
Detected outdoor unit number
P20
—
0
[
: IGBT short
1
[
: Fan motor position detective circuit error
3
[
: Fan motor trouble
P22
C
[
: TH sensor temp. error
(Heat sink overheat)
D
[
: TH sensor error
E
[
: Vdc output error
P26
01: Comp. 1 side
02: Comp. 2 side
P29
01: Comp. 1 side
02: Comp. 2 side
P31
—
Wireless remote controller
Sensor block display
of receiving unit
Operation
Timer
PRE, DEF.
Flash
l
¤
¤
ALT
¤
l
¤
ALT
¤
l
¤
ALT
¤
l
¤
ALT
¤
l
¤
ALT
l
¤
¤
ALT
l
¤
¤
ALT
l
¤
¤
ALT
¤
l
¤
ALT
¤
l
¤
ALT
¤
l
¤
ALT
¤
l
¤
ALT
¤
l
¤
ALT
¤
l
¤
ALT
¤
l
¤
ALT
¤
l
¤
ALT
Check code name
Indoor fan motor error
Discharge temp. TD1 error
High-pressure SW system operation
Phase-missing detection /Phase error
Heat sink overheat error
Indoor overflow error
Indoor fan motor error
Outdoor liquid back detection error
Gas leak detection
Discharge temp. TD2 error
4-way valve inverse error
High-pressure protective operation
Outdoor fan IPDU error
G-TR short protection error
Comp position detective circuit system error
Other indoor unit error
(Group terminal unit error)
Judging
device
Indoor
I/F
IPDU
I/F
IPDU,
I/F
Indoor
Indoor
I/F
I/F
I/F
I/F
I/F
IPDU
IPDU
IPDU
Indoor
Error detected by TCC-LINK central control device
Check code
Central
control
device
indication
C05
C06
C12
P30
Outdoor
7-segment display
Auxiliary code
—
—
—
—
—
—
—
—
Wireless remote controller
Sensor block display
of receiving unit
Operation Timer PRE, DEF. Flash
—
—
—
(L20 is displayed.)
Differs according to error contents
of unit with occurrence of alarm
Check code name
Sending error in TCC-LINK central control device
Receiving error in TCC-LINK central control device
Batch alarm of general-purpose equipment control
interface
Group control branching unit error
Duplicated central control addresses
Judging device
TCC-LINK
TCC-LINK
General-purpose equipment
I/F
TCC-LINK
TCC-LINK : TOSHIBA Carriea Cominication Link.