PRECAUTIONS FOR SAFETY

• Ensure that all Local, National and International regulations are satisfied.

• Read this “PRECAUTIONS FOR SAFETY” carefully before Installation.

• The precautions described below include the important items regarding safety.  Observe them without fail.

• After the installation work, perform a trial operation to check for any problem.

Follow the Owner’s Manual to explain how to use and maintain the unit to the customer.

• Turn off the main power supply switch (or breaker) before the unit maintenance.

• Ask the customer to keep the Installation Manual together with the Owner’s Manual.

CAUTION

New Refrigerant Air Conditioner Installation

• THIS AIR CONDITIONER ADOPTS THE NEW HFC REFRIGERANT (R410A) WHICH DOES NOT

DESTROY OZONE LAYER.

The characteristics of R410A refrigerant are ; easy to absorb water, oxidizing membrane or oil, and its pressure is
approx. 1.6 times higher than that of refrigerant R22.  Accompanied with the new refrigerant, refrigerating oil has also
been changed.  Therefore, during installation work, be sure that water, dust,  former refrigerant, or refrigerating oil
does not enter the refrigerating cycle.
To prevent charging an incorrect refrigerant and refrigerating oil, the sizes of connecting sections of charging port of
the main unit and installation tools are charged from those for the conventional refrigerant.
Accordingly the exclusive tools are required for the new refrigerant (R410A).
For connecting pipes, use new and clean piping designed for R410A, and please care so that water or dust does
not enter.  Moreover, do not use the existing piping because there are problems with pressure-resistance force and
impurity in it.

CAUTION

To Disconnect the Appliance from Main Power Supply

This appliance must be connected to the main power supply by means of a switch with a contact separation of at
least 3 mm.

 

 WARNING

• Ask an authorized dealer or qualified installation professional to install/maintain the air conditioner.

Inappropriate installation may result in water leakage, electric shock or fire.

• Turn off the main power supply switch or breaker before attempting any electrical work.

Make sure all power switches are off.  Failure to do so may cause electric shock.

• Connect the connecting wire correctly.

If the connecting wire is connected in a wrong way, electric parts may be damaged.

• When moving the air conditioner for the installation into another place, be very careful not to

enter any gaseous matter other than the specified refrigerant into the refrigeration cycle.

If air or any other gas is mixed in the refrigerant, the gas pressure in the refrigeration cycle becomes abnormally
high and it as a result causes pipe burst and injuries on persons.

• Do not modify this unit by removing any of the safety guards or by by-passing any of the safety

interlock switches.

• Exposure of unit to water or other moisture before installation may cause a short-circuit of

electrical parts.

Do not store it in a wet basement or expose to rain or water.

• After unpacking the unit, examine it carefully if there are possible damage.

• Do not install in a place that might increase the vibration of the unit.

• To avoid personal injury (with sharp edges), be careful when handling parts.

• Perform installation work properly according to the Installation Manual.

Inappropriate installation may result in water leakage, electric shock or fire.

• When the air conditioner is installed in a small room, provide appropriate measures to ensure that

the concentration of refrigerant leakage occur in the room does not exceed the critical level.

ENGLISH

Содержание MMK-AP0072H

Страница 1: ...DING ÅÃ ÅÉÑÉÄÉÏ ÅÃÊÁÔÁÓÔÁÓÇÓ SUPER MODULAR MULTI SYSTEM AIR CONDITIONER SMMS CLIMATISEUR SMMS KLIMAGERÄT SMMS CONDIZIONATORE D ARIA SMMS APARATO DE AIRE ACONDICIONADO SMMS AR CONDICIONADO SMMS AIRCONDITIONER SMMS ÊËÉÌÁÔÉÓÔÉÊÏ SMMS For commercial use Not accessible to the general public Pour usage commercial Vente interdite au grand public Nur für gewerbliche Nutzung kein öffentlicher Zugang Per us...

Страница 2: ...rement le contenu du Manuel du propriétaire et le remettre au client Wir danken Ihnen dass Sie sich für ein TOSHIBA Klimagerät entschieden haben Bitte lesen Sie diese Installations Handbuch bevor Sie Ihr Klimagerät benutzen sorgfältig Lassen Sie sich die Betriebsanleitung und das Installations Handbuch unbedingt vom Installateur oder vom Lieferanten aushändigen Eine Bitte an den Installateur oder ...

Страница 3: ...INSTALACIÓN ELÉCTRICA 108 10 CONTROLES APLICABLES 112 11 PRUEBA DE FUNCIONAMIENTO 114 12 RESOLUCIÓN DE PROBLEMAS 116 Acessórios e peças adquiridas localmente 121 1 PRECAUÇÕES DE SEGURANÇA 122 2 SELECÇÃO DO LOCAL DE INSTALAÇÃO 123 3 INSTALAÇÃO DA UNIDADE INTERIOR 125 4 ABRIR UM ORIFÍCIO E MONTAR A CHAPA DE INSTALAÇÃO 126 5 INSTALAÇÃO DATUBAGEM E MANGUEIRA DE DRENAGEM 127 6 FIXAÇÃO DA UNIDADE INTERI...

Страница 4: ...hape Usage Model RBC AMT21E Part No 1 2 Part name Q ty Installation plate 1 Wireless remote controller 1 Part No 3 4 Part name Q ty Battery 2 Remote controller holder 1 Part No 5 6 Part name Q ty Mounting screw Ø4 25 l x 6 Pan head wood screw Ø3 1 16 l 2 Others Name Owner s manual Installation manual Paper pattern Refrigerant piping Piping material used for the conventional refrigerant cannot be u...

Страница 5: ...ect the Appliance from Main Power Supply This appliance must be connected to the main power supply by means of a switch with a contact separation of at least 3 mm WARNING Ask an authorized dealer or qualified installation professional to install maintain the air conditioner Inappropriate installation may result in water leakage electric shock or fire Turn off the main power supply switch or breake...

Страница 6: ...e gas leaks and stays around the unit a fire may occur 2 SELECTION OF INSTALLATION PLACE WARNING Install the air conditioner where there is sufficient strength to weight of the unit If strength is insufficient the unit may fall down resulting in human injury Perform a specified installation work to guard against an earthquake An incomplete installation can cause accidents by the units failing and ...

Страница 7: ...t Rear left Right Rear right Bottom right For the rear left and left piping Wall Insert the cushion between the indoor unit and wall and tilt the indoor unit for better operation Bottom left 6 Pan head wood screw Hook 170mm or more 170mm or more 100 mm or more Hook 1 Installation plate Air filter Attach to the front panel Shield pipe When installing the Flow Selector Unit FS Unit keep a space more...

Страница 8: ...bundle it with PP band at positions other than specified Remote controller A place where there are no obstacles such as a curtain that may block the signal from the indoor unit Do not install the remote controller in a place exposed to direct sunlight or close to a heating source such as a stove Keep the remote controller at least 1m apart from the nearest TV set or stereo equipment This is necess...

Страница 9: ...ook 5 CAUTION Failure to firmly install the unit may result in personal injury and property damage if the unit falls In case of block brick concrete or similar type walls make 5mm dia holes in the wall Insert clip anchors for appropriate mounting screws NOTE Secure four corners and lower parts of the installation plate with 4 to 6 mounting screws to install it Projection 15mm or less 7 Mounting sc...

Страница 10: ... left slit for notching of the front panel A knife will produce flaws on the panel so use nippers 2 Changing drain hose For piping work at the left side lower left side and left back side it is necessary to change the drain hose and drain cap How to remove the drains cap Clip drain cap by needle nose pliers and pull out How to install the drain hose Firmly insert drain hose connecting part until h...

Страница 11: ...ing pipe through the pipe hole connect the connecting pipe to the auxiliary pipes and wrap the facing tape around them CAUTION Bind the auxiliary pipes two and connecting cable with facing tape tightly In case of leftward piping and rear leftward piping bind the auxiliary pipes two only with facing tape Carefully arrange pipes so that any pipe does not stick out of the rear plate of the indoor uni...

Страница 12: ...ult in dew dropping This air conditioner has the structure designed to drain water collected from dew which forms on the back of the indoor unit to the drain pan Therefore do not store the power cord and other parts at a height above the drain guide 1 Run the drain hose sloped downwards NOTE Hole should be made at a slight downward slant on the outdoor side 2 Put water in the drain pan and make su...

Страница 13: ...or unit Piping material and dimensions Piping material Model Pipe size mm Gas side Liquid side Phosphor deoxidization joint less pipe for air conditioner MMK AP0072H to MMK AP0122H Ø9 5 Ø6 4 Use a clean and new pipe and check that impurity such as dust oil moisture etc does not adhere in the pipe Pipe Forming End Positioning Flaring 1 Cut the pipe with a pipe cutter 2 Insert a flare nut into the p...

Страница 14: ...f m Airtight test Air purge etc For airtight test air purge addition of refrigerant and gas leak check follow the Installation Manual attached to the outdoor unit Open fully valves of the outdoor unit Gas leak check Check with a leak detector or soap water whether gas leaks or not from the pipe connecting section or cap of the valve REQUIREMENT Use a leak detector manufactured exclusively for HFC ...

Страница 15: ...es not come to contact with the high temperature part of the pipe The coating may melt resulted in an accident After connecting wires to the terminal blocks provide a trap and fix wires with the wire clamp Store the refrigerant piping line and control wiring line in the same line Do not turn on the power of the indoor unit until vacuuming of the refrigerant pipes completes Power supply specificati...

Страница 16: ...AUTION The remote controller wire Communication line and AC220 240V wires cannot be parallel to contact each other and cannot be stored in the same conduits If doing so a trouble may be caused on the control system due to noise etc Total wire length of remote controller inter unit wiring L1 L2 Ln Up to 500m Up to 400m Up to 200m Remote controller inter unit wiring Indoor unit Remote controller Ind...

Страница 17: ...ly open the lower part of the front panel then pull the upper part of the front panel toward you to remove it from the rear plate 4 After removing the front panel remove the wiring cover and the cord clamp 5 Connect and secure the power supply cable of flow selector unit and secure the cord clamp 6 The control wires are included in terminal block part of the power supply Take out the control wires...

Страница 18: ...sses according to the Installation Manual attached to the outdoor unit Terminal block for remote controller wiring of indoor unit A B Approx 200mm W White B Black W B Remote controller wire Local procure Wire from remote controller unit or sensor Connecting part Remote controller unit or sensor part Wire from remote controller or sensor Remote controller wiring Wire joint Header unit Follower unit...

Страница 19: ...es as shown in the figure Check that the displayed item code is 10 If the item code indicates other than 10 push button to erase the display and then retry the operation from the first step For some time after button has been pushed the operation of the remote controller cannot be accepted In a group control the firstly displayed indoor unit No becomes the header unit Every pushing UNIT button the...

Страница 20: ...C 6 C Adjustment of air direction 1 Using the remote controller switch change the up down air direction by moving the horizontal flap 2 Adjust the right left air direction by bending the vertical grille inside of the air outlet port with hands REQUIREMENT Do not touch the horizontal flap directly with hands otherwise a trouble may be caused For handling of the horizontal flap refer to Owner s Manu...

Страница 21: ...stop status 11 TEST RUN Before test operation Before turning on the power supply carry out the following items 1 Using 500V megger check there is 1MΩ or more between the terminal block of the power supply and the earth If 1MΩ or less is detected do not run the unit 2 Check that all the valves of the outdoor unit are fully opened Never push the electromagnetic contactor to carry out a forced test o...

Страница 22: ...tion changes to a forced cooling operation After approx 3 minutes a cooling operation starts forcedly Check cool air starts blowing If the operation does not start check wiring again 3 To stop a test operation push TEMPORARY button once again Approx 1 second The up down air flow adjusting plate closes and the operation stops Check transmission of remote controller 1 Push START STOP button of the r...

Страница 23: ...rating status or stop status Procedure 1 2 3 Description When pushing SET and buttons simultaneously for 4 seconds or more the right display appears If Service Check is displayed the mode enters in the error history mode 01 Order of error history is displayed in CODE No window Check Code is displayed in CHECK window Indoor unit address in which an error occurred is displayed in UNIT No Every pushi...

Страница 24: ... No of connected units E19 00 Header is nothing 02 Two or more header units E20 01 Outdoor of other line connected 02 Indoor of other line connected E23 E25 E26 No of outdoor units which received signal normally E28 Detected outdoor unit number 01 IPDU1 error 02 IPDU2 error 03 IPDU1 2 error E31 04 Fan IPDU error 05 IPDU Fan IPDU error 06 IPDU2 Fan IPDU error 07 All IPDU error Wireless remote contr...

Страница 25: ...ensor error TD1 sensor error TD2 sensor error TE1 sensor error TL sensor error TO sensor error Indoor TA sensor error TS1 sensor error TH sensor error Outdoor temp sensor miscabling TE TL Outdoor pressure sensor miscabling Pd Ps Ps sensor error Pd sensor error Indoor other error Indoor EEPROM error Compressor break down Magnet switch error Overcurrent relay operation Compressor trouble lock Curren...

Страница 26: ...oor overflow error Indoor fan motor error Outdoor liquid back detection error Gas leak detection Discharge temp TD2 error 4 way valve inverse error High pressure protective operation Outdoor fan IPDU error G TR short protection error Comp position detective circuit system error Other indoor unit error Group terminal unit error Error in indoor group Judging device Indoor I F IPDU I F IPDU I F Indoo...

Страница 27: ... alternately Used characters Characteristics of code classification Block display Check code in current system Hexadecimal notation 2 digits Few classification of communication incorrect setup system Indoor P C board Outdoor P C board Cycle Communication New check code Alphabet Decimal notation 2 digits Many classification of communication incorrect setup system Communication Incorrect setup 4 way...

Страница 28: ... the number of high concentration buildings however the installation of multi air conditioner systems is on the increase because of the need for effective use of floor space individual control energy conservation by curtailing heat and carrying power etc Most importantly the multi air conditioner system is able to replenish a large amount of refrigerant compared with conventional individual air co...

Страница 29: ... 0003 Have you changed lighting time of filter sign If not fill check mark in NO CHANGE and fill check mark in ITEM if changed respectively For check method refer to Applicable controls in this sheet Filter sign lighting time Filter sign lighting time Filter sign lighting time Filter sign lighting time Item code 01 Item code 01 Item code 01 Item code 01 o NO CHANGE o NO CHANGE o NO CHANGE o NO CHA...

Отзывы: