Toshiba MMD-UP0721HFP-E1 Скачать руководство пользователя страница 4

 3 

1

  Precautions for safety

The manufacturer shall not assume any liability for the damage 
caused by not observing the description of this manual.

 WARNING

General 

• Carefully read Owner’s Manual before starting the air conditioner. 

There are many important things to keep in mind for daily 
operation.

• Ask for installation to be performed by the dealer or a professional. 

Only a quali

fi

 ed installer (*1) is able to install an air conditioner. 

If a non-quali

fi

 ed person installs an air conditioner, it may result in 

problems such as 

fi

 re, electric shock, injury, water leakage, noise 

and vibration.

• Do not use any refrigerant different from the one speci

fi

 ed for 

complement or replacement. Otherwise, abnormally high pressure 
may be generated in the refrigeration cycle, which may result in a 
failure or explosion of the product or an injury to your body.

• Places where the operation sound of the outdoor unit may cause 

a disturbance. (Especially at the boundary line with a neighbor, 
install the air conditioner while considering the noise.)

• This appliance is intended to be used by expert or trained users in 

shops, in light industry, or for commercial use by lay persons.

Transportation and storage

• When transporting the air conditioner, wear shoes with protective 

toe caps, protective gloves, and other protective clothing.

• When transporting the air conditioner, do not take hold of the 

bands around the packing carton. You may injure yourself if the 
bands should break.

• When stacking the packing cartons for storage or transportation, 

heed the precautions written on the packing cartons. Failure to 
heed the precautions may cause the stack to collapse.

• You shall ensure that the air conditioner is transported in stable 

condition. If you 

fi

 nd any part of the product broken, contact your 

dealer.

Installation

• Only a quali

fi

 ed installer (*1) or quali

fi

 ed service person (*1) 

is allowed to carry out the electrical work of the air conditioner. 
Under no circumstances must this work be done by an unquali

fi

 ed 

individual since failure to carry out the work properly may result in 
electric shocks and/or electrical leaks.

• After the installation work has been completed, have the installer 

explain about the circuit breaker positions. In the event that error 
has occurred in the air conditioner, set the circuit breaker to the 
OFF position, and contact a service person.

• If you install the unit in a small room, take appropriate measures 

to prevent the refrigerant from exceeding the limit concentration 
even if it leaks. Consult the dealer from whom you purchased the 
air conditioner when you implement the measures. Accumulation 
of highly concentrated refrigerant may cause an oxygen de

fi

 ciency 

accident.

• Do not install the air conditioner in a location that may be subject 

to a risk of expire to a combustible gas. If a combustible gas leaks 
and becomes concentrated around the unit, a 

fi

 re may occur.

• Be sure to use the company-speci

fi

 ed products for the separately 

purchased parts. Use of non-speci

fi

 ed products may result in 

fi

 re, 

electric shock, water leakage, etc. Have the installation performed 
by a professional.

• Con

fi

 rm that earthing is performed correctly.

5-EN

6-EN

Содержание MMD-UP0721HFP-E1

Страница 1: ...ommercial use R410A AIR CONDITIONER MULTI TYPE Owner s Manual Indoor Unit Model name Fresh Air Intake Indoor Unit MMD UP0721HFP E1 MMD UP0961HFP E1 MMD UP1121HFP E1 MMD UP1281HFP E1 Owner s Manual 1 English ...

Страница 2: ...vironmentally friendly refrigerant According to IEC 60335 1 This appliance is not intended for use by person including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do no...

Страница 3: ...rations The qualified service person who is allowed to do the electrical work involved in installation repair relocation and removal has the qualifications pertaining to this electrical work as stipulated by the local laws and regulations and he or she is a person who has been trained in matters relating to electrical work on the air conditioners made by Toshiba Carrier Corporation or alternativel...

Страница 4: ...e packing cartons for storage or transportation heed the precautions written on the packing cartons Failure to heed the precautions may cause the stack to collapse You shall ensure that the air conditioner is transported in stable condition If you find any part of the product broken contact your dealer Installation Only a qualified installer 1 or qualified service person 1 is allowed to carry out ...

Страница 5: ...nd result in injury Do not place any combustion appliance in a place where it is directly exposed to the wind of air conditioner otherwise it may cause imperfect combustion When the air conditioner is operated with a combustion appliance in the same place be careful of ventilation to let fresh air enter the room Poor ventilation causes oxygen shortage When the air conditioner is used in a closed r...

Страница 6: ... injury Do not leave flammable sprays or other flammable materials near the air conditioner and do not spray flammable aerosol directly to the air conditioner They may catch fire If you have discovered that the fan grille is damaged do not approach the outdoor unit but set the circuit breaker to the OFF position and contact a qualified service person to have the repairs done Do not set the circuit...

Страница 7: ...as the fan is rotating at high speed inside the unit Ask for cleaning of the air conditioner to be performed by the dealer Cleaning the air conditioner in an improper manner may cause damage to plastic parts insulation failure of electric parts etc and result in a malfunction In the worst case it may result in water leakage electric shock smoke emission and fire Do not put a water container such a...

Страница 8: ...aker is thrown or some other occurrence 4 Service indicator Displayed while the protective device works or a check occurs 5 Test run indicator Displayed during test run 6 Temperature setting indicator The selected set temperature is displayed 7 Fan speed indicator Indicates the selected fan speed Auto Low Low Med Med High Fix 8 OFF timer indicator When a trouble occurs trouble code is displayed 9 ...

Страница 9: ...n ON OFF button Heat Cool Fan Auto Low Low Med Med High Operation mode and function COOL Cools the fresh air and sends it into the room HEAT Heats the fresh air and sends it into the room FAN Sends the fresh air as it is The fresh air intake unit controls temperature of the supply air so that it is close to the setup temperature of the remote controller However temperature of the supply air may no...

Страница 10: ...arge amount of oil droplets including machine oil or vapors Salty areas near oceans etc Hot springs emitting sulfidizing gas etc Heavily acidic or alkaline places Special maintenance or parts are required for use in the above places For details contact the dealer where you purchased the product Leave an enough space around the air intake and discharge of the outdoor unit so that the ventilation is...

Страница 11: ...ling and heating simultaneously When you attempt simultaneous operation indoor units performing cooling are stopped and the running preparation indicator is displayed on the remote controller An indoor unit performing heating continues running When you attempt an operation without the configured settings the running preparation indicator is displayed on the remote controller and operation stops If...

Страница 12: ...eard Sound is generated when the expansion valve operates when power has been turned on LCD blurs when it is touched LCD may temporarily blur by static electricity Check again Stops automatically Is the timer OFF Does not operate Is it a power failure Is the power switch turned off Is the power fuse or breaker blown Has the protective device operated The operation lamp goes on Is the timer ON The ...

Страница 13: ...en entered If Service check is displayed the mode enters in the troubleshooting history mode 01 Order of troubleshooting history appears in the temperature indicator The OFF timer indicator alternately shows the check code and the indoor Unit No in which the problem occurred 2 Each time the setting button is pushed the recorded troubleshooting history is displayed in sequence The troubleshooting h...

Страница 14: ...0721HFP E1 MMD UP0961HFP E1 MMD UP1121HFP E1 MMD UP1281HFP E1 Commercial name Super Modular Multi System Air Conditioner Super Heat Recovery Multi System Air Conditioner Mini Super Modular Multi System Air Conditioner MiNi SMMS series Complies with the provisions of the Machinery Directive Directive 2006 42 EC and the regulations transposing into national law Declaration of incorporation of partly...

Страница 15: ...1116950290 144 9 Moo 5 Bangkadi Industrial Park Tivanon Road Tambol Bangkadi Amphur Muang Pathumthani 12000 Thailand ...

Отзывы: