Status LED
The LED indicates the status of the Network Camera.
Hardware Reset
The reset button is used to reset the system or restore the factory default settings. Occasionally
resetting the system can return the camera to
normal operation. If the system problems remain
after resetting, restore the factory settings and install again.
Reset:Hold for about 3 seconds and release the recessed reset button
.
Wait for the Network
Camera to reboot.
Restore:Press and hold the recessed reset button until the status LED rapidly blinks. It takes
about 10 seconds. Note that all settings will be restored to factory default. Upon successful
restore, the status LED will blink during normal operation.
Restoring the factory defaults will erase any previous settings.
Item
LED status
Description
1
Red
LED steady ON
Red
LED OFF
Power on and system booting
Power off
2
Steady
Red
+ Blink
Green
every 1 sec.
Red
LED Steady ON +
Green
LED OFF
Network works (heartbeat)
Network fail
3
Blink
Red
every 0.15 sec. + Blink
Green
every 1 sec. Upgrading F/W
4
Blink
Red
every 0.15 sec. + Blink
Green
every 0.15 sec. Restoring default