- 5 -
5. CONNECTIONS AND OPERATIONS
Notes on connecting
• Power plugs to connected equipment must be disconnected before installation.
• A 75-ohm coaxial cable (3C-2V or 5C-2V) is required for standard connection.
• For details of wiring and operation of equipment to be connected, refer to their
operation manuals.
• Coaxial cables for video signals and the power cord are not supplied with the
camera.
Refer to the operations manuals of connected equipment for detailed wiring and
overall operation instructions.
5-1 Basic connection single system configuration
24V AC UL Listed Class 2 power supply / 12V DC power supply
CAUTION : Never input 24V AC and 12V DC at the same time.
In case of DC12V, connect “+12” to red cable and “GND” to black cable.
Do not overload power supply
Since this camera uses 24V AC UL Listed Class 2 power supply or 12V DC power
supply, it should be connected to a power supply that allows for at least 5w
consumption. Because the IK-VR01A uses a mechanism, a sufficient power supply
with adequate current specifications is required.
Video Monitor
AC 120V
12V DC
BNC Connector
Supplied Power Connector
( ) POWER CORD (twisted pair line)
minimum wire size of 18 AWG is recommended.
Содержание IK-VR01A