background image

- 2 -

• The CAUTION label, shown on the left,

is attached on the camera.

The lightening flash with arrowhead
symbol, within an equilateral triangle,
is intended to alert the user to the
presence of uninsulated “dangerous
voltage” within the product’s enclosure
that may be of sufficient magnitude to
constitute a risk of electric shock to
persons.

The exclamation point within an
equilateral triangle is intended to alert
the user to the presence of important
operating and maintenance (servicing)
instructions in the literature
accompanying the appliance.

WARNING :
TO REDUCE THE RISK OF FIRE OR
ELECTRIC SHOCK, DO NOT EXPOSE
THIS APPLIANCE TO RAIN OR
MOISTURE.

CAUTION :
CONNECT 24V AC UL LISTED CLASS 2
POWER SUPPLY.

FIELD INSTALLATION :
WORDED : “THIS INSTALLATION SHOULD
BE MADE BY A QUALIFIED SERVICE
PERSON AND SHOULD CONFORM TO
ALL LOCAL CODES.”

FCC NOTICE
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own expense.

USER-INSTALLER CAUTION : Your authority to operate this FCC verified equipment could be
voided if you make changes or modifications not expressly approved by the party.

CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK.
DO NOT REMOVE COVER (OR BACK).
NO USER SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

Serial No Label
The serial No. label is located here.

Содержание IK-VR01A

Страница 1: ...tions 3 3 Components 3 4 Part Names Functions 4 5 Connections and Operations 5 6 Installations 7 7 Line Lock Phase 12 8 Note on use and Installation 12 9 In Case of Problems 13 10 Specifications 14 11 Exterior View 15 Record in space provided below the Model No and the Serial No as found on the label on the bottom of this unit Model No IK VR01A Serial No Retain this information for future referenc...

Страница 2: ...aged 13 Lightning For added protection for this video product during a lightning storm or when it is left unattended and unused for long periods of time unplug it from the wall outlet and disconnect the power supply and cable system This will prevent damage to the video product due to lightning and power line surges However if there is thunder or lightning now do not touch the unit and any connect...

Страница 3: ...NOTICE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance ...

Страница 4: ...rs If necessary use a soft cloth moistened with alcohol to wipe off any dust 2 Avoid aiming the camera at the sun 3 Avoid shooting the camera at intense light Intense light such as a spotlight may cause a bloom or smear A vertical stripe may appear on the screen However this is not a malfunction 4 Install the camera away from video noise If cables are wired near electric lighting wires or a TV set...

Страница 5: ...era synchronization to line lock with the switch on Available only with AC24V Lens Iris ADJ Monitor Out Connector Connect with the supplied monitor out harness wire Used to adjust the angle of view when installing the camera Line Lock Phase ADJ Counterclockwise The picture becomes darker Clockwise The picture becomes brighter Optimum Value is at default setting Adjusts the phase of the line lock ...

Страница 6: ...nstructions 5 1 Basic connection single system configuration 24V AC UL Listed Class 2 power supply 12V DC power supply CAUTION Never input 24V AC and 12V DC at the same time In case of DC12V connect 12 to red cable and GND to black cable Do not overload power supply Since this camera uses 24V AC UL Listed Class 2 power supply or 12V DC power supply it should be connected to a power supply that all...

Страница 7: ...e camera is synchronized to the power frequency of 60 1Hz covering a normal fluctuation of the power frequency However the camera may not cover a large fluctuation caused from the power generated by an engine generator etc It takes about 10 seconds or more until a stable synchronization is obtained after the power is turned on This is normal because several seconds are required to stabilize the ca...

Страница 8: ...kg The camera unit including the mounting base and the bracket weighs 2 1kg When installing to surfaces of other materials use the screws to fix it firmly 6 1 Adjust the Angle of View a Top Cover Security screws Camera Base 1 Loosen the three security screws by the supplied special hexangular wrench and remove the top cover Important Notice Be sure to remove three silver screws a immediately after...

Страница 9: ...djustment turn pan lock 1 clockwise to fasten it Note Do not turn the lens over 360 Otherwise the inner connector may be broken and the image may not appear 3 The lens tilt angle can be adjusted by loosening the tilt lock 2 After adjusting tighten the tilt lock 2 4 Adjust the zoom position by loosening the zoom lock lever 3 After adjusting tighten the zoom lock lever 3 5 Adjust the focus by loosen...

Страница 10: ...amera base with three supplied screws A Longer screw M4x16 Tighten and lock the screws firmly Cable access hole ø27 mm Cable access hole ø27 mm With female screw for piping 55 mm 55 mm 83 5 mm 83 5 mm 85 mm 85 mm 46 mm 46 mm 7 7 When installing the camera unit on the wall mount it with the drain groove on the downside Do not block the drain groove When installing the camera unit outdoor make water...

Страница 11: ...amera base with three supplied screws B Shorter screw M4x10 Tighten and lock the screws firmly Align the marks Align to this mark Mount the top cover the assembly of the top dome cover and secure it firmly with three security screws by the supplied special hexangular wrench Note the direction of the bracket which has two sides Junction Box ...

Страница 12: ...amper Shock damper cushion Note the direction of the damper cushion The groove should be face up Dome cover Gasket Top cover Dome replacement When the dome cover is damaged or to be replaced by a transparent cover call your distributor or sales person Firmly tighten three mounting screws Take care not to let dirt or foreign object enter between the parts ...

Страница 13: ...ction Never touch internal parts Do not touch the internal parts of the camera other than the parts specified Otherwise the camera may malfunction Do not splash water on the camera Install the camera where the camera can be kept dry If the camera gets wet turn off the power and contact your dealer Check the ambient temperature and humidity Avoid using the camera where the temperature is hotter or ...

Страница 14: ...nts Are the camera and connected equipment turned on Are cables connected correctly Is the monitor TV adjusted correctly Is the lighting too weak Is the lens focus adjusted Is the lens or cover dirty Are there any large barrier or bright illumination near the camera Is the lens iris adjustment volume correctly set ...

Страница 15: ...on 1 3 IT CCD 771 H x 492 V 2 1 Interlace 15 734KHz Horizontal 59 94Hz Vertical 480 TV lines 50dB TYP White 100 Weight On SC TRAP ON 0 2 lux More than 10 of image output Clear dome cover 0 4 lux More than 10 of image output Tint dome cover Average AGC 24dB Auto Iris Lens Auto 2500 K 10000 K Provided VR range 300deg 0 45 On Off DIP SW VBS 1 0Vp p 75ohm unbalance BNC Internal for DC or Linelock for ...

Страница 16: ... 15 11 EXTERIOR VIEW φ 175 48 5 110 155 unit mm SR 45 5 ...

Страница 17: ... 16 61 5 φ 170 SR 45 5 147 5 150 41 unit mm ...

Страница 18: ... 17 4 M4 46 120 83 5 120 110 60 4 φ 4 5 4 φ 6 5 unit mm 4 4 46 83 5 85 85 7 40 15 15 40 15 15 55 5 20 82 114 4 φ 6 5 6 φ 5 5 φ 27 4 M6 Depth 10 Bracket Mounting Base ...

Страница 19: ... 18 ...

Отзывы: