7
4. CONNECTION
4. 1 Standard Connection
IK-TF9C
DC IN 12V
Lens (not included)
Cable (not included)
Frame grabber board,
image process
equipment etc.
Monitor
DC power
supply
(not included)
Less than 4 mm
DC IN 12V
Connector used:
HR10A-7P-4PB
(HIROSE electronics
Co. Ltd) or equivalent.
DIGITAL
Function
I/O
1 +12V
1
2 +12V
2
3 GND
3
4 GND
4
5
6
7
8
9
10
11
12
13
GND
X0-
X1-
X2-
Xcllk-
X3-
SerTC+
SerTFG-
CC1-
CC2+
CC3-
CC4+
GND
14
15
16
17
18
19
20
21
22
23
24
25
26
–
O
O
O
O
O
I
O
I
I
–
–
–
GND
X0+
X1+
X2+
Xcllk+
X3+
SerTC-
CC1+
CC2-
CC3+
CC4-
Serial communication control (RXD)
Serial communication control (TXD)
Trigger pulse input
Partial scanning control
NC
NC
GND
1
1
13
26
14
2
4
3
Connector used:
12226-51000-00
(3M) or equivalent.
4. 2 Cautions on Connection
• When connecting the camera cables, unplug the power source of the camera and the other equipment
connected.
• We suggest using a C mount lens made for a 3CCD camera.
When using another lens, the best camera performance of this camera may not be obtained.
(For example, low resolution may occur, focus may be lost through the range of a zoom lens, and
flare, ghost or shading may occur)
Furthermore, in order to avoid damaging the mounting portion of the camera head, use a lens which
has projection dimension from the mounting base of less than 0.157"(4mm).
• For DC power supply connecting to DC IN 12V terminal, use UL listed and/or CSA approved ungrounding
type AC adaptor with the specifications described below.
Power supply voltage
: 12V DC±10%
Current rating
: More than 830 mA
Ripple voltage
: Less than 50 mV(p–p)
Connector
: HR10A–7P–4S by HIROSE electronics Co. Ltd
Pins 1, 2 : 12V
Pins 3, 4 : GND
• Use the standard cable for Camera Link.
4. 3 Connector Pin Assignments