37
BEFORE MAKING A SERVICE CALL
10.
Symptom
Items to be checked
No image
• Is the power supplied correctly?
• Is the lens iris adjusted correctly?
• Are the cables connected correctly?
• Is the shutter mode set correctly?
• Is the image process equipment set correctly?
Poor color
• Is the monitor adjusted correctly?
• Is the white balance of the camera adjusted correctly?
• Is there enough illumination?
SPECIFICATIONS
11.
Power supply
DC 10V ~ DC 13.2V
Power consumption
Approx. 3.1W (When the DC power supply is 12V)
Pick-up system
RGB, 3CCD
Image sensor
1/3inch All pixels CCD
(Effective pixels Horizontal : 1034, Vertical : 779)
Scanning System
Progressive scan
Video output pixels
Horizontal pixels : 1024, Vertical : 768
Pixel clock frequency
29.5MHz
Sync signal frequency
Horizontal : 23.229kHz, Vertical : 29.18Hz
Sync system
Internal/External (Automatic switching)
Sensitivity
F6.8 standard (2000 lx, 3000K)
Minimum illumination
14 lx (F2.2, Sensi 18 dB, 3000K)
Lens mount
C mount (flange back : 17.526 mm in-air)
Ambient temperature
0 to 40°C (32 to 104°F)
Ambient humidity
Less than 90%
Weight
Approx. 158g (0.338lbs)
External dimension
44 (W) x 44 (H) x 78 (D) mm
(1.73” (W) x 1.73” (H) x 3.07” (D)) (except for protruded portion)
White balance
AWB (Automatic white balance), MANUAL (Manual)
Gain
MANUAL (Manual), OFF (0 dB)
Partial scanning
40fps, 42fps, 50fps, 60fps, 70fps, 80fps, 90fps
Output signal
8-bit RGB, Digital output (Camera Link format)
Sync signal output
FVAL, LVAL, DVAL (Positive polarity)
Pixel Clock
External sync input
HD : CC3 (LVDS input) Negative polarity
VD : CC4 (LVDS input) Negative polarity
External trigger input
CC1 (LVDS input), More than 2 μs pulse width
Partial scanning control
signal input
CC2 (LVDS input)
Interface
Serial data interface : Ser TC (RXD), Ser TFG (TXD)
The designs and specifications are subject to change without notice.
If any change occurs, we will revise the manual, etc.
120730c1_IK_TF7P2_EN.indd 37
12.7.30 1:19:05 PM