30
PW SR (Pulse width trigger SYNC-RESET)
( 4 )
The trigger input to the CC1 of the DIGITAL terminal develops 1 frame images.
1 Pulse Width Trigger SYNC-RESET Picture Output Timing
(4. 1)
Exposure completion
0 to 1H
Negative polarity mode
Positive polarity mode
FVAL
About 1
µ
s
About 7
µ
s
Exposure period*
2
Trigger*
1
(Internal VD)*
3
*
4
RGB data
(video interval image)
LVAL,
DVAL
28H
(
Partial scanning OFF
)
25H
(
Partial scanning 40fps
)
27H
(
Partial scanning 42fps
)
33H
(
Partial scanning 50fps
)
39H
(
Partial scanning 60fps
)
43H
(
Partial scanning 70fps
)
46H
(
Partial scanning 80fps
)
48H
(
Partial scanning 90fps
)
*1: External input signal
*2: Exposure time = Trigger pulse width + 6 µs
(Valid trigger pulse width is 2 µs or greater for external trigger shutter operation.)
*3: VD is generated after 0 to 1H following the completion of the exposure period and the video is synchronized to
this and output.
*4: When NR is set to ON, 1H is increased.
Note:
When the next trigger is input before completion of the output of the video corresponding to the trigger, there
will be an effect on the video.
120730c1_IK_TF7P2_EN.indd 30
12.7.30 1:19:04 PM