28
1P SR (1 Pulse Trigger Sync Reset)
( 2 )
Charge begins to accumulate after the trigger input to CC1 of the DIGITAL terminal, the vertical sync signal is reset
and frame images are output.
1 Pulse Trigger SYNC-RESET Picture Output Timing
(2. 1)
About 1
µ
s
Exposure completion
0 to 1H*
3
Exposure period*
2
Trigger*
1
Negative polarity mode
Positive polarity mode
(Internal VD)
FVAL
RGB data
(video interval image)
LVAL,
DVAL
28H
(
Partial scanning OFF
)
25H
(
Partial scanning 40fps
)
27H
(
Partial scanning 42fps
)
33H
(
Partial scanning 50fps
)
39H
(
Partial scanning 60fps
)
43H
(
Partial scanning 70fps
)
46H
(
Partial scanning 80fps
)
48H
(
Partial scanning 90fps
)
*
4
*1: External input signal
*2: Exposure time is determined by the setting of “7. 2 (1.3) Changing each setting in E.TRG mode”.
*3: VD is generated after 0 to 1H following the completion of the exposure period and the video is synchronized to
this and output.
*4: When NR is set to ON, 1H is increased.
Note:
When the next trigger is input before completion of the output of the video corresponding to the trigger, there
will be an effect on the video.
120730c1_IK_TF7P2_EN.indd 28