26
Synchro. Scan Operation
7. 3
The shutter speed can be set by the horizontal scanning period (1H) or by the number of frames.
Setting by 1H
( 1 )
1H/796H ~ 795H/796H stands for the setting by the 1H and the shutter speed can be set by the 1H (43.05 µs).
When operating Partial Scanning or binning, the number’s listed below can be used for setting.
Partial scanning OFF
Partial scanning 40fps, E.40fps
Partial scanning 42fps, E.42fps
Partial scanning 50fps, E.50fps
Partial scanning 60fps, E.60fps
Partial scanning 70fps, E.70fps
Partial scanning 80fps, E.80fps
Partial scanning 90fps, E.90fps
1H/796H ~ 795H/796H
1H/580H ~ 579H/580H
1H/553H ~ 552H/553H
1H/465H ~ 464H/465H
1H/387H ~ 386H/387H
1H/332H ~ 331H/332H
1H/290H ~ 289H/290H
1H/258H ~ 257H/258H
Setting by the frame
( 2 )
2FRM to 512FRM stand for the setting (long period exposure) by the frame.
The video signal stored during the frame period set is output as 1 frame video image at a frame interval specified.
(4FRM setting)
n+1
n
RGB data
(video interval image)
(Internal VD)
FVAL
LVAL,
DAVL
120730c1_IK_TF7P2_EN.indd 26