28
(3. 2) Pulse Width Trigger SYNC-NON RESET Picture Output Timing (at Time of Internal Sync)
*1: Externally input signal
*2: Exposure time = Trigger pulse width + 6
µ
s
(Valid trigger pulse width is 2
µ
s or greater for external trigger shutter operation.)
*3: As long as there is no external sync input, the internal VD will be output when SJ01 is set to HD/VD output
position.
*4: Video is output at the falling edge of the internal VD following completion of the exposure period.
The video and FVAL/LVAL/DVAL have a paired relationship.
Note:
When the next trigger is input before completion of the output of the video corresponding to the trig-
ger, there will be an effect on the video.
About 1
µ
s
Exposure period*
2
Trigger*
1
Exposure period*
2
Negative polarity mode
Positive polarity mode
About 7
µ
s
(Internal VD)*
3
RGB data
(video interval image)
FVAL
LVAL,
DVAL
28H (Partial scanning OFF)
38H (Partial scanning 60fps)
47H (Partial scanning 90fps)