27
( 3 ) PW SNR (Pulse width trigger SYNC-NON RESET)
The trigger input to CC1 of the DIGITAL terminal develops 1 frame images.
(3. 1) Pulse Width Trigger SYNC-NON RESET Picture Output Timing
(At Time of One-shot or Continuous External VD/Continuous External HD Input)
*1: Externally input signal
*2: Exposure time = Trigger pulse width + 6
µ
s
(Valid trigger pulse width is 2
µ
s or greater for external trigger shutter operation.)
*3: Video is output at the falling edge of the internal VD following completion of the exposure period.
The video and FVAL/LVAL/DVAL have a paired relationship.
Note:
When the next trigger is input before completion of the output of the video corresponding to the trig-
ger, there will be an effect on the video.
About 1
µ
s
Exposure period*
2
External VD IN*
1
External HD IN*
1
About 7
µ
s
About 1H
Negative polarity mode
Positive polarity mode
Exposure period*
2
Trigger*
1
(Internal VD)
RGB data
(video interval image)
FVAL
LVAL,
DVAL
The internal VD falling edge is within the
exposure period and thus video is not output. *
3
28H (Partial scanning OFF)
38H (Partial scanning 60fps)
47H (Partial scanning 90fps)