- 27 -
2
1 PULSE SR
1 Pulse Sync Reset
Charge begins to accumulate after the trigger input to the RGB terminal, the vertical sync signal is reset and
field images are output.
(a) Rising edge / Falling edge mode
The exposure time is set to 0.02 ms to 16 ms on the menu.
Trigger pulse level
(Low Level)
Less than 0.5V , (High Level)
3.4V to 5V
RGB terminal
Trigger pulse fetch timing
Rising edge / Falling edge selectable
Trigger pulse width
More than 2
s
Trigger pulse interval
More than 33.5 ms
Exposure end
11 to 12H
Approx. 1.9
s
INDEX
Video output
Falling edge mode
TRIGGER
(RGB terminal)
VD output
Index output
Exposure period
Rising edge mode
(b) Width mode
Trigger pulse width
More than 4
s Less than 255FRM
Trigger pulse interval
17.5ms (From exposure end to next exposure start.)
Negative
Positive
Exposure start
Exposure end
Exposure end
11 to 12H
INDEX
Video output
TRIGGER
(RGB terminal)
VD output
Index output
Exposure period
Approx. 1.9
s
Approx. 1.9
s