background image

20

11. SPECIFICATIONS

10. TROUBLESHOOTING CHART

Symptoms

No image

Possible causes

• Is power properly supplied?
• Is the lens iris adjusted properly?
• Is the CRT monitor adjusted properly?
• Is the shutter mode set correctly?

* Design and specifications are subject to change without notice.

Power supply

Power consumption

Image sensor
(Effective pixels)

Scanning system

Scan frequency

Sensitivity

Lens mount

Ambient temperature

Ambient humidity

Weight

External dimension

Gain

Video output

Electric shutter

Mode

Partial scanning

Sync signal output

External trigger input

Optional parts

DC12 

±

 10%

Approx. 1.7W

2/3inch  Progressive Scanning CCD
(Horizontal: 1392 pixels, Vertical: 1040 pixels)

Noninterlace

Horizontal: 15.998 kHz, Vertical: 14.98 Hz

F16  600 lx (GAIN OFF)

C mount

32 to 104

°

 F (0 to 40

°

C)

Less than 90%

Approx. 4.77 oz (135g)

1.73" (W) x 1.73" (H) x 2.05" (D)
(44 (W) x 44 (H) x 52 (D) mm)     (except for protruded portion)

ON (-3 to 12 dB), OFF (0 dB)

IK-SX1L: EIA RS-644 LVDS video 8-bit digital output
IK-SX1:

Camera link video 8-bit digital output

1/15s, 1/100s, 1/500s, 1/1000s, 1/2000s, 1/4000s,
1/10000s, 1/50000s

Internal synchronization, internal synchronization draft,
internal synchronization partial scanning
1-Pulse trigger, 1-pulse trigger partial scanning
Pulse width trigger, Pulse width trigger partial scanning

Scanning area 1/15 (70 lines, 6 fps)
Scanning area 1/2.6 (400 lines, 30 fps)
Scanning area 1/2 (560 lines, 24 fps)
Scanning area 2/3 (700 lines, 20 fps)

HD, VD/LEN, FEN

LVDS format (IK-SX1L)
Camera Link format (IK-SX1)

PCK (28.63636 MHz) LVDS format  (IK-SX1L)

Camera Link format (IK-SX1)

TRIGGER; Low level: Less than 0.4V, High level: 3.4 to 5V

Negative
More than 20

µ

s pulse width

EXC-SX03M (cable for IK-SX1L), EXC-SX03A (cable for IK-
SX1L), EXC-CL05 (cable for IK-SX1), etc.

Содержание IK-SX1

Страница 1: ...ul interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio com munications Operation of this equipment in a residential area is likely to cause harmful interfer ence in which case the user will be requir...

Страница 2: ...c shock Do not repair disassemble and or modify by yourself This may cause fire and or electric shock Be always sure to contact your dealer for internal repair check and cleaning of the product Keep the rated voltage for the product The use of power supply voltage except for its rated voltage may cause fire and or electrical shock Please refer to 4 Connections Do not put a vessel s filled with a l...

Страница 3: ...e and or fire Do not put the product in your mouse and do not swallow it This may cause suffocation and or injury Ask your dealer to perform a periodical check and internal cleaning approx once every five years Dust inside the product may cause fire and or trouble For check and cleaning cost please consult your dealer Disclaimer We disclaim any responsibility and shall be held harmless for any dam...

Страница 4: ...11 7 1 Internal synchronization 11 7 2 Internal synchronization draft mode 11 7 3 Internal synchronization partial readout 12 7 4 1 pulse trigger 13 7 5 1 pulse trigger partial readout 13 7 6 Pulse width trigger 14 7 7 Pulse width trigger partial readout 14 8 Partial Scanning 15 8 1 Scanning area 1 15 70 lines 60 fps 15 8 3 Scanning area 1 2 560 lines 24 fps 15 8 2 Scanning area 1 2 6 400 lines 30...

Страница 5: ...his is not a malfunction Operating ambient temperature and hu midity Do not use the camera in places where temperature and humidity exceed the specifications Picture quality will lower and internal parts may be damaged Be particularly careful when using in places exposed to direct sunlight When shooting in hot places depending on the conditions of the object and the camera for example when the gai...

Страница 6: ...Selects the electric shutter exposure time Selects the partial scanning mode 4 4 4 4 4 GAIN control volume Adjusts the video signal gain when the gain mode is set to ON with the MODE SELECT switch 3 3 3 3 3 5 5 5 5 5 DIGITAL terminal IK SX1L Outputs the EIA RS 644 LVDS 8 bit digital signal Enters a trigger signal IK SX1 Outputs the Camera Link signal 8 bit digital signal Enters a trigger signal 3 ...

Страница 7: ...ay not be obtained For example low resolution may occur and flare ghost or shading may occur For DC power supply connecting to DC IN 12V terminal use UL listed and or CSA approved ungrounding type AC adaptor with the specifications described below Power supply voltage DC12V 10 Current rating More than 830 mA Less than 2 5A Ripple voltage Less than 50 mV p p Connector HR10A 7P 4S by HIROSE electron...

Страница 8: ...1 2 3 4 5 6 7 8 9 10 11 12 13 GND X0 X1 X2 Xclk X4 NC NC CC1 Trigger input CC2 Partial Scanning setting CC3 Partial Scanning setting CC4 Partial Scanning setting GND 14 15 16 17 18 19 20 21 22 23 24 25 26 GND X0 X1 X2 Xclk X4 NC NC CC1 Trigger input CC2 Partial Scanning setting CC3 Partial Scanning setting CC4 Partial Scanning setting GND DIGITAL 1 13 14 26 1 14 15 28 5 OPERATION 1 1 1 1 1 Referri...

Страница 9: ...nning area ON 1 2 3 4 5 6 7 8 9 0 Mode Gain OFF Gain ON No 1 OFF ON 3 to 12dB variable with the control volume Mode HD VD LEN FEN No 2 OFF ON Mode Internal synchronization 1 pulse trigger Pulse width trigger Internal synchronization draft mode Internal synchronization partial scanning 1 pulse trigger partial scanning Pulse width trigger partial scanning Internal synchronization partial scanning No...

Страница 10: ... 700 lines 20 fps No 9 OFF OFF ON ON No 0 OFF ON OFF ON Switch No 3 on the rear panel OFF OFF OFF OFF OFF DIGITAL terminal CC2 H H H H L DIGITAL terminal CC3 H H L L DIGITAL terminal CC4 H L H L Don t care Either L or H is OK 6 5 Partial scanning switch This sets the partial scanning area Partial scanning can also be set from the DIGITAL terminal on the rear panel Setting from the DIGITAL terminal...

Страница 11: ...tput signal Video data pixel clock FEN VD LEN HD Video data video period image HD VD FEN LEN 7 2 Internal synchronization draft mode When the draft mode is set the frame rate can be increased by thinning out the image when outputting Horizontal synchronization 15 998 kHz Vertical synchronization 60 fps Output signal Video data pixel clock FEN VD LEN HD HD VD FEN LEN Video data video period image ...

Страница 12: ...t lines is 70 400 560 700 lines For the detail refer to 8 Partial Scanning Horizontal synchronization 15 998 kHz 28 63636 MHz x 1790 clocks Output signal Video data pixel clock FEN VD LEN HD Output Output Draft mode OFF All pixels are independently read out Draft mode ON Pixels are thinned out and read out Only the white pixel is read out HD VD FEN LEN Video data video period image ...

Страница 13: ... the rear panel Input signal Trigger Output signal Video data pixel clock FEN VD LEN HD Exposure period Video data video period image HD Trigger VD FEN LEN 7 5 1 pulse trigger partial readout This is the mode for partial scanning by the 1 pulse trigger operation Input signal Trigger Output signal Video data pixel clock FEN VD LEN HD HD Trigger VD FEN LEN Video data video period image Exposure peri...

Страница 14: ... The trigger signal mini mum pulse width L period is 20µs 1 50000s Input signal Trigger Output signal Video data pixel clock FEN VD LEN HD HD Trigger VD FEN LEN Video data video period image Exposure period 7 7 Pulse width trigger partial readout This is the mode for partial scanning by the pulse width trigger operation Input signal Trigger Output signal Video data pixel clock FEN VD LEN HD HD VD ...

Страница 15: ... is partially scanning and the frame rate can be increased 8 1 Scanning area 1 15 70 lines 60 fps 8 2 Scanning area 1 2 6 400 lines 30 fps 8 3 Scanning area 1 2 560 lines 24 fps 8 4 Scanning area 2 3 700 lines 20 fps 70 lines 400 lines 560 lines 700 lines ...

Страница 16: ... Timing Chart 9 1 All pixel scanning 1 V rate Internal synchronization 1 pulse trigger pulse width trigger 1068H VD FEN Video output 1040H 11H 9H 8H Video period VD FEN 1040H 2H 9H Video output Video period ...

Страница 17: ... H rate 1790 HD LEN 1392 402 180 4 The digits indicate the number of clocks 1 clock 34 9 ns 28 63636 MHz Video output Video period 9 2 Draft mode 1 V rate 267H VD FEN 260H 1H 1H 9H Video output Video period ...

Страница 18: ...180 Video period The digits indicate the number of clocks 1 clock 34 9 ns 28 63636 MHz VD FEN 99H 66H 50H 36H 9H 70H 400H 560H 700H 98H 65H 49H 35H 276H 540H 668H 780H Video output Total Sweep off period Sweep off period Video period 70 lines readout 400 lines readout 560 lines readout 700 lines readout ...

Страница 19: ...80H VD internal synchronization output position VD output position Video output Total Sweep off period Sweep off period Video period 70 lines readout 400 lines readout 560 lines readout 700 lines readout HD LEN Video output Video period The digits indicate the number of clocks 1 clock 34 9 ns 28 63636 MHz 4 180 402 1392 1790 ...

Страница 20: ...o 104 F 0 to 40 C Less than 90 Approx 4 77 oz 135g 1 73 W x 1 73 H x 2 05 D 44 W x 44 H x 52 D mm except for protruded portion ON 3 to 12 dB OFF 0 dB IK SX1L EIA RS 644 LVDS video 8 bit digital output IK SX1 Camera link video 8 bit digital output 1 15s 1 100s 1 500s 1 1000s 1 2000s 1 4000s 1 10000s 1 50000s Internal synchronization internal synchronization draft internal synchronization partial sc...

Страница 21: ... SX1 44 1 73 22 0 87 26 1 02 12 0 47 12 0 47 12 0 47 44 1 73 3 M3 screw depth 4mm 0 16 26 1 02 26 1 02 4 M3 screw depth 4mm 0 16 35 1 38 35 1 38 35 1 38 10 5 0 41 10 5 0 41 11 57 0 46 45 5 1 79 59 2 32 23 0 91 7 0 28 11 0 43 39 1 54 2 5 0 10 7 3 0 29 33 1 30 11 0 43 15 9 0 63 45 5 1 79 13 0 51 6 0 24 28 1 10 Dimensions mm inch ...

Страница 22: ...22 Memo ...

Страница 23: ...23 Memo ...

Страница 24: ...NG ANY DIRECT OR INDIRECT DAMAGES LOST PROFITS LOST SAVINGS OR OTHER SPECIAL INCIDENTAL EXEMPLARY OR CONSEQUENTIAL DAMAGES WHETHER FOR BREACH OF CONTRACT TORT OR OTHERWISE OR WHETHER ARISING OUT OF THE USE OF OR INABILITY TO USE SUCH PRODUCT EVEN IF TAIS ITS PARENT COMPANY OR AN ASP HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR OF ANY CLAIM BY ANY OTHER PARTY SOME STATES DO NOT ALLOW THE ...

Отзывы: