background image

- 9 -

7. LINE LOCK PHASE

When a video switcher switches two or more cameras, the picture may fluctuate on the
video monitor due to the different AC line phase of each camera. In this case, adjust the
V PHASE controller to get a stable image.

8. NOTE ON USE AND INSTALLATION

• Do not aim the camera at the sun

Do not aim the camera at the sun or point it at sun even if you are not shooting.

• Do not shoot intense light

Intense light such as a spotlight may cause a bloom or smear. A vertical stripe may
appear on the screen. However, this is not a malfunction.

• Treat the camera with care

Do not drop the camera or subject it to strong shock of vibration. Otherwise, the camera
may malfunction.

• Never touch internal parts

Do not touch the internal parts of the camera other than the parts specified. Otherwise,
the camera may malfunction.

• Do not splash water on the camera

Install the camera where the camera can be kept dry. If the camera gets wet, turn off
the power and contact your dealer.

• Check the ambient temperature and humidity

Avoid using the camera where the temperature is hotter or colder than specified.
Otherwise, the quality of images may deteriorate or internal parts may be affected.
Special care is required to use the camera at high temperature and humidity.

• Should you notice any trouble

If any trouble occurs while you are using the camera, turn off the power and contact
your dealer. If you continue to use the camera when there is something wrong with it,
the trouble may much worse and an unpredictable accident may occur.

V PHASE CONTROL

Содержание IK-DF01A

Страница 1: ...utions 3 3 Components 3 4 Part Names Functions 4 5 Connections and Operations 5 6 Installations 7 7 Line Lock Phase 9 8 Note on use and Installation 9 9 In Case of Problems 10 10 Specifications 11 11 Exterior View 12 Record in space provided below the Model No and the Serial No as found on the label on the bottom of this unit Model No IK DF01A Serial No Retain this information for future reference...

Страница 2: ...ction for this video product during a lightning storm or when it is left unattended and unused for long periods of time unplug it from the wall outlet and disconnect the power supply and cable system This will prevent damage to the video product due to lightning and power line surges 13 Overloading Do not overload power supply and extension cords as this can result in a risk of fire or electric sh...

Страница 3: ...CAL CODES Note The camera is indoor used INFORMATION This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energ...

Страница 4: ... or using it under direct sunlight rain or dust 2 Avoid touching the CCD sensor with your fingers If necessary use a soft cloth moistened with alcohol to wipe off any dust 3 When the camera is not in use keep the lens cap attached to protect the CCD sensor 4 Avoid aiming the camera at the sun 5 Avoid shooting the camera at intense light Intense light such as a spotlight may cause a bloom or smear ...

Страница 5: ...it after completing the adjustment Tilt ADJ Screws Turn the screws to adjust the lens tilt angle Fasten and lock them after the adjustment completes V Phase ADJ Cut with a knife or scissors and insert the cables through the knockout so the cables will not pinched when installed The Bottom mark indicates the lens position The Bottom mark should be on the top when installing in a ceiling Adjusts the...

Страница 6: ...ions manuals of connected equipment for detailed wiring and overall operation instructions 5 1 Basic connection single system configuration 24V AC UL Listed Class 2 power supply 12V DC power supply CAUTION Never input 24V AC and 12V DC at the same time In case of DC12V connect 12 to red cable and GND to black cable Do not overload power supply Since this camera uses 24V AC UL Listed Class 2 power ...

Страница 7: ...bed at the time of switching Note The camera is synchronized to the power frequency of 60 1Hz covering a normal fluctuation of the power frequency However the camera may not cover a large fluctuation caused from the power generated by an engine generator etc It takes about 10 seconds or more until a stable synchronization is obtained after the power is turned on This is normal because several seco...

Страница 8: ... φ4mm 6 1 Adjust the Angle of View 1 The lens direction in pan direction can be adjusted by turning ring 1 left to unfasten it without moving the lens After adjustment turn the ring 1 right to fasten it Note Do not turn the lens over 360 Otherwise the inner connector may be broken and the image may not appear 2 The lens direction at the tilt angle can be adjusted by turning screw 2 After adjustmen...

Страница 9: ...ength Otherwise the inner connector may be broken and the image may not appear 2 Reverse the camera head 180 from default setting and install it The direction of the camera head is shown as above With the Bottom mark 2 upwards the tilt range is adjusted as shown above 3 Fasten the screw 1 to fix the camera head 1 2 Tilt Range Bottom Mark Camera Head 6 3 Installing the Cover As shown in the illustr...

Страница 10: ...alfunction Never touch internal parts Do not touch the internal parts of the camera other than the parts specified Otherwise the camera may malfunction Do not splash water on the camera Install the camera where the camera can be kept dry If the camera gets wet turn off the power and contact your dealer Check the ambient temperature and humidity Avoid using the camera where the temperature is hotte...

Страница 11: ...equipment turned on Is the mode setting switch DC AES set to OFF Be sure to set to ON Are cables connected correctly Is the monitor TV adjusted correctly Is the lighting too weak Is the lens focus adjusted Is the lens or cover dirty Are there any large barrier or bright illumination near the camera Is the lens iris adjustment volume correctly set ...

Страница 12: ...ental Operating Temperature Storage Temperature 7 Regulation Safety Emission 1 4 IT CCD 768 H x 494 V 2 1 Interlace 15 734KHz Horizontal 59 94Hz Vertical 480 TV lines 50dB TYP AGC Off Weight On 0 2 lux More than 10 of image output Clear cover 0 5 lux More than 10 of image output Smoke cover Average AGC 24dB Auto Iris Lens Auto 2500 K 10000 K Provided VR range 300deg 0 45 On Off DIP SW VBS 1 0Vp p ...

Страница 13: ... 12 11 EXTERIOR VIEW φ110 φ5 96 83 5 Unit mm ...

Страница 14: ... 13 Wall 2 hold φ3 2 1 8 driver depth about 40mm 2 TP4 X 37 ...

Страница 15: ... 14 ...

Страница 16: ......