11
•
Pulse Width Trigger Mode (Setting by Trigger Pulse Width)
Set all dip switches (1 to 4) of the rear panel to “OFF”.
An arbitrary shutter speed is obtained by setting the width of the trigger pulse to 2
µ
s or
greater.
Shutter speed = Trigger pulse width + 6
µ
sec
NOTE
When the next trigger is input before completion of the output of the video corresponding to
the trigger, there will be an effect on the video.
1
2
3
4
•
Pulse Width Trigger SYNC-NON RESET Picture Output Timing (at Time of Internal Sync)
*1: Externally input signal
*2: Exposure time = Trigger pulse width + 6
µ
s
(Valid trigger pulse width is 2
µ
s or greater for external trigger shutter operation.)
*3: As long as there is no external sync input, the internal VD will be output when the rear
panel HD/VD signal input/output switch is set to the INT side.
*4: Video is output at the falling edge of the internal VD following completion of the exposure
period.
The video and the VIDEO INDEX have a paired relationship.
NOTE
When the next trigger is input before completion of the output of the video corresponding to
the trigger, there will be an effect on the video.
About 1
µ
s
Exposure period*
2
Video output
525H
(
Partial scanning OFF)
175H
(
Partial scanning ON)
VIDEO INDEX
VD OUT*
3
Trigger*
1
Exposure period*
2
Negative polarity mode
Positive polarity mode
About 7
µ
s
Содержание IK-52V