46
8-2.
Operation Mode
and Control
Method
12) AUTO operation
An auto operation sets the water temperature TSC_F depending on the outside air temperature TO.
1) How to operate
• Pressing the remote controller [ZONE1, 2] button and then the [AUTO] button starts AUTO operation for heating.
• During an AUTO operation, pressing again the [AUTO] button returns to the usual manual set heating operation.
• The remote controller displays "A" as the temperature during an AUTO operation.
(When 2-temperature control is enabled, the remote controller displays "A".)
• Long-pressing the [AUTO] button during an AUTO operation activates the Auto-Curve FC change mode, enabling
the set Auto-Curve water temperature to be shifted by ±5K range (FC_27). When using the auto curve shift function
please note the maximum and minimum water temperature at 60 °C and 20 °C respectively.
• Even if the temperature setting is changed during an AUTO operation, the operation continues.
• An AUTO operation works with a heating operation only, not with a cooling or a hot water supply operation.
<ZONE1>
• An operation starts at the set temperature of straight -line approximation for the following: water temperature A °C
with the outside temperatureT0 °C, B °C with T1 °C, C °C with T2 °C, D °C with T3 °C, and E °C with 20 °C.
<ZONE2>
• Set temperature of the ZONE2 can be selected from two methods (FC_A2). One is a percentage of ZONE1, the other
is a fixed value.
FC_A2 = "0" : Percentage method that is set by FC_31.
FC_A2 = "1" : Fixed value method that is set by FC_A3, A4 and A5.
However, it is automatically controlled the set temperature of ZONE1 to be the ZONE2 or more.
Item
Operation flow and applicable data, etc.
TSC_F(°C)
A(40)
B(35)
C(30)
D(25)
E(20)
T0
(-20)
T2=0
20 TO
T1
(-10)
T3
(10)
± 5K adjustable (FC 27)
(°C)
Related FC
FC No.
Setting item
Default
range
2C
Setting temperature A at T0
40
20~60 °C
2D
Setting temperature B at T1
35
20~60 °C
2E
Setting temperature C at T2 (= 0
°C
)
30
20~60 °C
2F
Setting temperature D at T3
25
20~60 °C
30
Setting temperature E at 20
°C
20
20~60 °C
A1
Outside temperature T0
-20
-30~-20 °C
29
Outside temperature T1
-10
-15~0 °C
2B
Outside temperature T3
10
0~15 °C
27
Set temperature shift with heating set to auto
0
-5 to 5K
TSC_F(°C)
A'(40)
B'(35)
E'(20)
T0
(-20)
20 TO (°C)
T1
(-10)
FC_A2=1 Fixed value method
TSC_F(°C)
A(40)
B(35)
C(30)
D(25)
E(20)
T0
(-20)
T2=0
20 TO (°C)
T1
(-10)
T3
(10)
ZONE 1
ZONE 2
80 % (FC_31) of ZONE1
FC_A2=0 Percentage method
Auto-Curve in ZONE2 shows 80% (FC) of that of ZONE1,
the water temperature setting does not fall below 20 °C.
The ZONE2 set temperature A' °C with the outside
temperature T0 °C, B' °C with T1 °C, E' °C with 20 °C.
Related FC
FC No.
Setting item
Default
range
A2
The choice of how to set ZONE2
0
0 or 1
A3
Setting temperature A' at T0
40
20~60 °C
A4
Setting temperature B' at T1
35
20~60 °C
A5
Setting temperature E' at 20 °C
20
20~60 °C
31
Auto-Curve ratio of ZONE2
80
0~100%
AMP Air Conditioning
www.ampair.co.uk | [email protected]