AIR TO WATER HEAT PUMP

Hydro Unit

Model name:

HWS-455XWHM3-E
HWS-805XWHM3-E
HWS-805XWHT6-E
HWS-805XWHT9-E
HWS-1405XWHM3-E
HWS-1405XWHT6-E
HWS-1405XWHT9-E

Owner’s Manual

English

Содержание HWS-1405XWHM3-E

Страница 1: ...AIR TO WATER HEAT PUMP Hydro Unit Model name HWS 455XWHM3 E HWS 805XWHM3 E HWS 805XWHT6 E HWS 805XWHT9 E HWS 1405XWHM3 E HWS 1405XWHT6 E HWS 1405XWHT9 E Owner s Manual English ...

Страница 2: ...order to prevent destruction of the ozone layer This appliance is not intended for use by person including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with ...

Страница 3: ...ere is water leak Therefore the Hydro Unit is recommended to be installed in a room with waterproof flooring and drainage systems Products and parts to be used in combination with this product must be specified products and parts that meet prescribed specifications If unspecified products or parts are used a failure smoke fire or electric shock may be caused Operation warnings Avoid injury or dama...

Страница 4: ...carefully before operating the Air to Water Heat Pump system Do not install the Air to Water Heat Pump in special purpose rooms such as a ship or any kind of vehicle Doing so could harm machine performance When the Air to Water Heat Pump is operated together with a combustion device in the same place pay careful attention to ventilation and let fresh air into the room Poor ventilation can cause an...

Страница 5: ...eaks everyday Do not touch the water pipes refrigerant pipes or joints These may become extremely hot Do not drink water produced by the Air to Water Heat Pump After extended use fresh water may become contaminated by the Hydro Unit due to deterioration of pipe materials etc If fresh water contains solid matter is discolored turbid or smells DO NOT DRINK IT Call for equipment inspection immediatel...

Страница 6: ...r etc 4 MENU button On the top screen Displays the MENU screen On the other screen Fixes or copies setting the parameter value 5 button On the top screen Select the heating or cooling mode On the other screen Varies its function according to the screen 6 button On the top screen Select the hot water mode On the other screen Varies its function according to the screen 7 RETURN button Returns to the...

Страница 7: ...ide the hydro unit is energized during a heating operation Lights while the compressor is acting for hot water supply operation Lights while the electric cylinder heater is energized during hot water operation Lights when heating is selected Lights when cooling is selected Lights during hot water supply is selected Lights while internal pump pump 1 or expansion pump pump 2 is driven Lights when th...

Страница 8: ...ally running Lights when Anti bacteria operation is set to ON and hot water operation is selected Lights while Frost protection operation is actually running Lights when Test mode or Floor drying is set to ON Displays when the remote controller is set as Second remote controller Lights when an error occurs and goes out when the error is cleared Lights when an error occurs This number is unit numbe...

Страница 9: ...p running When the ON OFF button is pressed all the operations heating or cooling and hot water stop Changing the temperature 1 Press the button to select the mode to change the temperature 2 Press the button to adjust the temperature The ZONE2 setting temperature must be equal to or lower than the ZONE1 setting temperature You can choose whether to use water temperature or room temperature as set...

Страница 10: ...tting Schedule setting Model information Service information Information Clock Screen contrast Backlight Key lock Header Second Temperature control Language Condition setting Holiday setting Page 10 Page 10 Page 11 Page 11 Page 12 Page 13 Page 13 Page 15 Page 15 Page 16 Page 16 Page 17 Page 17 Page 17 Page 18 Page 18 Page 21 Page 21 Page 21 Page 21 Page 21 9 EN ...

Страница 11: ... button to select Data value then press the button to adjust the temperature between 5K to 5 K 3 Press the button The set temperature is registered Schedule timer This function is available only for the header remote controller Schedule setting makes the following modes to be flexibly set hot water supply heating cooling hot water supply and heating hot water supply and cooling and stop and set te...

Страница 12: ...appears FC No 0E Start time Range 0 23 Default 22 0F End time Range 0 23 Default 06 2 Press the button to select FC number or Data then press the button to set the value The same value cannot be set to 0E and 0F 3 Press the button The set time is registered Silent mode This function is available only for the header remote controller This setting is used to reduce noise output from the outdoor unit...

Страница 13: ... Use this function when hot water is not used for a long time or before using a large amount of hot water The preset time and temperature settings can be changed to values with in a range of 30 to 180 minutes and 40 to 80 C Ask the installation company to make the required changes to the settings Start the hot water operation before making the setting It may not be able to go to the setting screen...

Страница 14: ...FC number or Data then press the button to set the value 3 Press the button The set value is registered Frost protection This function performs operation with the minimum capacity target water temperature 15 C to prevent pipes from freezing in case the unit is not used for a long period due to absence Cancel schedule timer to start frost protection operation When frost protection is operated with ...

Страница 15: ...r the header remote controller 1 Press the button for 4 seconds or longer on the Fig 3 05 screen to enter the setting mode The function code setting screen appears FC No 12 End days Range 0 20 Default 0 13 End times Range 0 23 Default 0 ex Code No 12 05 13 13 5 days 13 hours 2 Press the button to select FC number or Data then press the button to set the value 3 Press the button The set value is re...

Страница 16: ...tting screen then press the button 2 Press the button to select the date month year and time 3 Press the button to set the value then press the button The clock display appears on the top screen The clock display blinks if the clock setting has been reset due to power failure or other cause Anti bacteria MENU 2 2 Frost protection Setting Information SET Initial setting Setting Schedule setting SET...

Страница 17: ... button to select Backlight on the Initial setting screen then press the button 2 Press the button to select ON OFF then press the button The back light of the LCD is turned on as factory default The back light is on for about 30 seconds after button operation Clock Initial setting 1 2 Screen contrast Backlight Header Second SET Temperature control Screen contrast FIX Clock Initial setting 1 2 Scr...

Страница 18: ...remote controller Disable function with second remote controller Schedule timer Silent mode Schedule setting Temperature control To control room temperature instead of water temperature with this remote controller Please check with the installer for details Language Select a language for the screen text 1 Press the button to select Language on the Initial setting screen then press the button 2 Pre...

Страница 19: ... the button 5 Press the button to Fix Mode Operation mode HEAT COOL HW Hot water Z1 ZONE1 setting temperature Z2 ZONE2 setting temperature HW Hot water supply operation setting temperature Start Operation start time 0 00 23 59 End Operation end time 0 00 24 00 means the operation continues If End time is set earlier than Start time an error is displayed Anti bacteria MENU 2 2 Frost protection Sett...

Страница 20: ...t End Monday Tuesday Hot water supply operation 1 When a day of the week is specified Set individually about Monday and Tuesday 2 When use the ALL setting If you want to set up two or more days you can set up easily using the function Set about ALL then it will be similarly set up from Monday to Sunday If there are some days you don t want to do Schedule operation do Holiday setting after that 20 ...

Страница 21: ...2 Press the button then the contents of the setting is cleared Condition setting 1 2 ALL MON WED THU FRI SAT SUN Mode Start End SET DAY COPY RESET Z1 Z2 HW TUE Copy the previous day setting Condition setting NO YES 55 45 08 00 22 00 25 23 00 65 18 00 19 00 Condition setting 1 2 ALL MON WED THU FRI SAT SUN Mode Start End COPY RESET Z2 HW Z1 COOL HEAT TUE HW SET DAY 55 45 08 00 22 00 25 23 00 65 18 ...

Страница 22: ...ed the key cannot be used during Key lock and schedule timer The factory default is UNLOCK Information 1 Press the button to select Information on the MENU screen then press the button Model Information Shows the model names and serial numbers 1 Press the button to select Model information on the Information screen then press the button Service information Shows the contact number for service 1 Pr...

Страница 23: ...side and brought into the room This way of heating is called heat pump system When the outside temperature is too low it is recommended to use another heating apparatus in combination with the air to water heat pump Attention to snowfall and freeze on the outdoor unit In snowy areas the air intake and air discharge of the outdoor unit are often covered with snow or frozen up If snow or freeze on t...

Страница 24: ... 3 08 3 10 3 07 2 89 Refrigerant R410A Dimension HxWxD mm 630x800x300 890x900x320 1 340x900x320 Outdoor unit with Cord heater HWS 1105H8 E HWS 1405H8 E HWS 1605H8 E HWS 1105H8R E HWS 1405H8R E HWS 1605H8R E Power supply 380 400 V 3N 50 Hz Type INVERTER Function Heating Cooling Heating Capacity kW 11 2 14 0 16 0 11 2 14 0 16 0 Input kW 2 34 3 16 3 72 2 34 3 16 3 72 COP 4 80 4 44 4 30 4 80 4 44 4 30...

Страница 25: ...V 3N 50 Hz for hot water cylinder heater option 220 230 V 50 Hz Leaving water temperature Heating C 20 55 Cooling C 7 25 Hydro Unit HWS 1405XWHM3 E HWS 1405XWHT6 E HWS 1405XWHT9 E Back up heater capacity kW 3 0 6 0 9 0 Power supply for back up heater 220 230 V 50 Hz 380 400 V 3N 50 Hz 380 400 V 3N 50 Hz for hot water cylinder heater option 220 230 V 50 Hz Leaving water temperature Heating C 20 55 ...

Страница 26: ...the installation company Room is not cooled or heated Is scheduled operation set Check whether scheduled operation is set Is night setback operation set Check the setting on the remote controller Is the air to water heat pump operating in Auto mode In Auto mode the target value is set automatically according to the outdoor unit temperature The Auto mode can be adjusted Contact the installation com...

Страница 27: ... 26 Hydro Unit Owner s Manual ...