© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO281c/351c/451c
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 53
2
391-0
Image
control
Output value
display of
image quality
sensor
Lowden-
sity pat-
tern Y
ALL
0
<0-1023>
M
Displays the output
value of image quality
sensor when a low-den-
sity test pattern is writ-
ten.
The larger the value is,
the smaller the toner
amount adhered
becomes.
10
391-1
Lowden-
sity pat-
tern M
ALL
0
<0-1023>
M
10
391-2
Lowden-
sity pat-
tern C
ALL
0
<0-1023>
M
10
391-3
Lowden-
sity pat-
tern K
ALL
0
<0-1023>
M
10
392
Image
control
Light amount adjustment
result of image quality sen-
sor
ALL
0
<0-255>
M
The LED light amount
adjustment value of this
sensor is the reference
value to set the
reflected light from the
belt surface.
2
393
Image
control
Relative humidity display
during latest closed-loop
control
ALL
0
<0-100>
M
Displays the relative
humidity at the latest
performing of the
closed-loop
control.
2
394
Image
control
Enforced performing of
image quality open-loop
control
ALL
-
-
Performs the image
quality open-loop con-
trol.
6
395
Image
control
Enforced performing of
image quality closed-loop
control
ALL
-
M
Performs the image
quality closedloop con-
trol.
6
396
Image
control
Image quality control initial-
ization
ALL
-
M
Performs the image
quality control, initialize
each control value.
6
398-0
Image
control
Target value
of the high
image den-
sity control
Y
ALL
265
<220-
360>
M
Sets the target value of
high image density con-
trol at the time of the
image quality control.
4
398-1
M
ALL
300
<220-
360>
M
4
398-2
C
ALL
320
<220-
360>
M
4
398-3
K
ALL
370
<300-
420>
M
4
401
Laser
Fine adjustment of polygo-
nal motor rotation speed
(reproduction ratio adjust-
ment)
PRT
134
<0-255>
M
When the value
increases by “1”, the
reproduction ratio of pri-
mary scanning direction
increases by approx.
0.07%. (approx. 0.1
mm/step)
1
405
PPC
135
<0-255>
M
1
410
Laser
Adjustment of primary
scanning laser writing start
position
PPC
128
<0-255>
M
When the value
increases by “1”, the
writing start position
shifts to the front side
by approx. 0.0423 mm.
1
411
PRT
120
<0-255>
M
1
Adjustment mode (05)
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM
Contents
Pro-
cedur
e
06/10
Содержание e-studio281c
Страница 6: ......
Страница 12: ......
Страница 368: ...e STUDIO281c 351c 451c 2005 2008 TOSHIBA TEC CORPORATION All rights reserved ADJUSTMENT 3 102 ...
Страница 406: ...e STUDIO281c 351c 451c 2005 2008 TOSHIBA TEC CORPORATION All rights reserved PREVENTIVE MAINTENANCE PM 4 38 ...
Страница 618: ...e STUDIO281c 351c 451c 2005 2008 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 6 60 ...
Страница 672: ...e STUDIO281c 351c 451c 2005 2008 TOSHIBA TEC CORPORATION All rights reserved DATA CLONING with USB STORAGE DEVICE 9 26 ...
Страница 674: ...e STUDIO281c 351c 451c 2005 2008 TOSHIBA TEC CORPORATION All rights reserved WIRE HARNESS CONNECTION DIAGRAMS 10 2 ...
Страница 677: ......
Страница 678: ......