e-STUDIO281c/351c/451c
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
ADJUSTMENT
3 - 54
<Procedure>
1) Attach the lens unit and fix it temporarily with 2 screws.
2) Match the center scale of the plate in which the unit is to be installed and the rightmost scale of
the adjusting hole on the lens unit plate.
Fig. 3-22
3) Tighten 5 screws securely to fix the lens unit while pushing it to the rear side and fix 2 ground
wires with the screws.
Fig. 3-23
Screw
[Rear]
[Front]
[Rear]
[Front]
Screw
Screw
Screw