e-STUDIO281c/351c/451c
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 136
702
Mainte-
nance
Remote-controlled service
function
ALL
2
<0-2>
SYS
0: Valid (Remote-con-
trolled server)
1: Valid (L2)
2: Invalid
1
703
Mainte-
nance
Remote-controlled service
HTTP server
URL setting
ALL
-
SYS
Maximum 256 Bytes
11
704-0
Interruption of
stapling oper-
ation (no sta-
ple)
Copying
ALL
1
<0-1>
SYS
0: Continues printing
by switching sort
setting
1: Interrupts printing
4
704-1
Printing /
BOX print-
ing
ALL
0
<0-1>
SYS
0: Continues printing
by switching sort
setting
1: Interrupts printing
4
707
Mainte-
nance
Remote-controlled service
HTTP initially-registered
server
URL setting
ALL
https://
device.mf
p-sup-
port.com:
443/
device/fir-
streg-
ist.ashx
SYS
Maximum 256 Bytes
11
710
Mainte-
nance
(Remote)
Short time interval setting
of recovery from Emer-
gency Mode
ALL
24
<1-48>
SYS
Sets the time interval to
recover from the Emer-
gency Mode to the Nor-
mal Mode.
(Unit: Hour)
1
711
Mainte-
nance
Short time interval setting
of Emergency Mode
ALL
60
<30-360>
SYS
Unit: Minute
1
715
Mainte-
nance
Remote-controlled service
periodical polling timing
(Hour/Hour/Minute/Minute)
ALL
1230
SYS
0 (0:00) to 2359 (23:59)
1
716
Mainte-
nance
Remote-controlled service
Writing data of self-diag-
nostic code
ALL
0
<0-1>
SYS
0: Prohibited
1: Accepted
1
717
Mainte-
nance
Remote-controlled service
response waiting time
(Timeout)
ALL
3
<1-30>
SYS
Unit: Minute
1
718
Mainte-
nance
Remote-controlled service
initial registration
ALL
0
<0-3>
SYS
0: OFF
1: Start
2: Only certification is
scanned
3: Satellite communi-
cation starts
1
719
Mainte-
nance
Remote-controlled service
tentative password
ALL
-
SYS
Maximum 10 letters
11
720
Mainte-
nance
Status of remote-con-
trolled service initial regis-
tration (Display only)
ALL
0
<0-1>
SYS
0: Not registered
1: Registered
2
721
Mainte-
nance
Service center call function
ALL
2
<0-2>
SYS
0: OFF
1: Notifies all service
calls
2: Notifies all but
paper jams
1
723
Mainte-
nance
Service center call HTTP
server URL setting
ALL
-
SYS
Maximum 256 letters
11
Setting mode (08)
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM
Contents
Pro-
cedur
e
Содержание e-studio281c
Страница 6: ......
Страница 12: ......
Страница 368: ...e STUDIO281c 351c 451c 2005 2008 TOSHIBA TEC CORPORATION All rights reserved ADJUSTMENT 3 102 ...
Страница 406: ...e STUDIO281c 351c 451c 2005 2008 TOSHIBA TEC CORPORATION All rights reserved PREVENTIVE MAINTENANCE PM 4 38 ...
Страница 618: ...e STUDIO281c 351c 451c 2005 2008 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 6 60 ...
Страница 672: ...e STUDIO281c 351c 451c 2005 2008 TOSHIBA TEC CORPORATION All rights reserved DATA CLONING with USB STORAGE DEVICE 9 26 ...
Страница 674: ...e STUDIO281c 351c 451c 2005 2008 TOSHIBA TEC CORPORATION All rights reserved WIRE HARNESS CONNECTION DIAGRAMS 10 2 ...
Страница 677: ......
Страница 678: ......