© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO281c/351c/451c
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 125
2
569
Image
control
Image quality closed-loop
control automatic start-up/
Temperature setting of
fuser roller at power-ON
ALL
(color)
8
<0-20>
M
Sets the fuser roller
temperature to perform
closed-loop control
when “1” or “2” (valid) is
set in 08-559.
0: 20°C 1: 25°C
2: 30°C 3: 35°C
4: 40°C 5: 45°C
6: 50°C 7: 55°C
8: 60°C 9: 65°C
10: 70°C 11: 75°C
12: 80°C 13: 85°C
14: 90°C 15: 95°C
16: 100°C 17: 105°C
18: 110°C 19: 115°C
20: 120°C
1
570
Image
control
Image quality closed-loop
control automatic start-up/
Relative humidity differ-
ence setting
ALL
(color)
4
<0-6>
M
Sets the relative humid-
ity difference to per-
form the closed-loop
control when “1” or “2”
(valid) is set in 08-565.
0: 0%
1: 5%
2: 10%
3: 15%
4: 20%
5: 25%
6: 30%
1
571
Image
control
Image quality closed-loop
control automatic start-up/
Setting of period of time
unattended
ALL
(color)
4
<0-24>
M
Sets the period of time
unattended to perform
closed-loop control
when “1” or “2” (valid) is
set in 08-566.
Setting value x 1 (hour)
1
572
Image
control
Image quality closed-loop
control automatic start-up/
Setting of accumulated
print volume
ALL
(color)
10
<0-30>
M
Sets the number of
accumulated print vol-
ume to perform closed-
loop control when “1” or
“2” (valid) is set in 08-
567.
Setting value x 100
(pages)
1
573
Image
control
Abnormality detection
count (Y)
Display/0 clearing
ALL
0
<0-16>
M
Counts the abnormality
detection of image qual-
ity control. Accumulat-
ing total of [CE10],
[CE20] and [CE40]
1
574
Image
control
Abnormality detection
count (M)
Display/0 clearing
ALL
0
<0-16>
M
Counts the abnormality
detection of image qual-
ity control. Accumulat-
ing total of [CE10],
[CE20] and [CE40]
1
575
Image
control
Abnormality detection
count (C)
Display/0 clearing
ALL
0
<0-16>
M
Counts the abnormality
detection of image qual-
ity control. Accumulat-
ing total of [CE10],
[CE20] and [CE40]
1
576
Image
control
Abnormality detection
count (K)
Display/0 clearing
ALL
0
<0-16>
M
Counts the abnormality
detection of image qual-
ity control. Accumulat-
ing total of [CE10],
[CE20] and [CE40]
1
Setting mode (08)
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM
Contents
Pro-
cedur
e
Содержание e-studio281c
Страница 6: ......
Страница 12: ......
Страница 368: ...e STUDIO281c 351c 451c 2005 2008 TOSHIBA TEC CORPORATION All rights reserved ADJUSTMENT 3 102 ...
Страница 406: ...e STUDIO281c 351c 451c 2005 2008 TOSHIBA TEC CORPORATION All rights reserved PREVENTIVE MAINTENANCE PM 4 38 ...
Страница 618: ...e STUDIO281c 351c 451c 2005 2008 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 6 60 ...
Страница 672: ...e STUDIO281c 351c 451c 2005 2008 TOSHIBA TEC CORPORATION All rights reserved DATA CLONING with USB STORAGE DEVICE 9 26 ...
Страница 674: ...e STUDIO281c 351c 451c 2005 2008 TOSHIBA TEC CORPORATION All rights reserved WIRE HARNESS CONNECTION DIAGRAMS 10 2 ...
Страница 677: ......
Страница 678: ......