© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO281c/351c/451c
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 115
2
411
Fuser
Fuser roller temperature on
standby (Center ther-
mistor)
ALL
12
<0-16>
M
0: 120°C 1: 125°C
2: 130°C 3: 135°C
4: 140°C 5: 145°C
6: 150°C 7: 155°C
8: 160°C 9: 165°C
10: 170°C 11: 175°C
12: 180°C 13: 185°C
14: 190°C 15: 195°C
16: 200°C
1
412-0
Fuser
Fuser roller temperature
during printing
(Center thermistor/Thick
paper 3)
ALL
(black)
12
<0-16>
M
0: 120°C 1: 125°C
2: 130°C 3: 135°C
4: 140°C 5: 145°C
6: 150°C 7: 155°C
8: 160°C 9: 165°C
10: 170°C 11: 175°C
12: 180°C 13: 185°C
14: 190°C 15: 195°C
16: 200°C
4
412-1
ALL
(color)
12
<0-16>
M
4
413-0
Fuser
Fuser roller temperature
during printing
(Center thermistor/Thick
paper 1)
ALL
(black)
12
<0-16>
M
0: 120°C 1: 125°C
2: 130°C 3: 135°C
4: 140°C 5: 145°C
6: 150°C 7: 155°C
8: 160°C 9: 165°C
10: 170°C 11: 175°C
12: 180°C 13: 185°C
14: 190°C 15: 195°C
16: 200°C
4
413-1
ALL
(color)
12
<0-16>
M
4
415-0
Fuser
Period of time retaining
print-start temperature
(Thick paper 3)
ALL
(black)
3
<0-10>
M
0: Invalid 1: 1 sec.
2: 2 sec
3: 3 sec
4: 4 sec. 5: 5 sec.
6: 6 sec. 7: 7 sec.
8: 8 sec. 9: 9 sec.
10: 10 sec.
4
415-1
ALL
(color)
2
<0-10>
M
4
416
Fuser
Temperature setting to
start solving abnormality
(Center/Side thermistor/
Thick paper 3)
ALL
9
<0-12>
M
0: 120°C 1: 125°C
2: 130°C 3: 135°C
4: 140°C 5: 145°C
6: 150°C 7: 155°C
8: 160°C 9: 165°C
10: 170°C 11: 175°C
12: Invalid
1
417-0
Fuser
Pre-running time for first
printing (Thick paper 3)
ALL
(black)
16
<0-16>
M
0: Invalid
1: 0 sec.
2: 2 sec.
3: 3 sec.
4: 4 sec.
5: 5 sec.
6: 6 sec.
7: 7 sec.
8: 8 sec.
9: 10 sec.
10: 12 sec. 11: 14 sec.
12: 16 sec. 13: 18 sec.
14: 20 sec. 15: 25 sec.
16: 30 sec.
4
417-1
ALL
(color)
0
<0-16>
M
4
422
Fuser
Fuser roller temperature
setting at the end of pre-
running during warming-up
ALL
4
<0-16>
M
0: 120°C 1: 125°C
2: 130°C 3: 135°C
4: 140°C 5: 145°C
6: 150°C 7: 155°C
8: 160°C 9: 165°C
10: 170°C 11: 175°C
12: 180°C 13: 185°C
14: 190°C 15: 195°C
16: 200°C
1
Setting mode (08)
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM
Contents
Pro-
cedur
e
Содержание e-studio281c
Страница 6: ......
Страница 12: ......
Страница 368: ...e STUDIO281c 351c 451c 2005 2008 TOSHIBA TEC CORPORATION All rights reserved ADJUSTMENT 3 102 ...
Страница 406: ...e STUDIO281c 351c 451c 2005 2008 TOSHIBA TEC CORPORATION All rights reserved PREVENTIVE MAINTENANCE PM 4 38 ...
Страница 618: ...e STUDIO281c 351c 451c 2005 2008 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 6 60 ...
Страница 672: ...e STUDIO281c 351c 451c 2005 2008 TOSHIBA TEC CORPORATION All rights reserved DATA CLONING with USB STORAGE DEVICE 9 26 ...
Страница 674: ...e STUDIO281c 351c 451c 2005 2008 TOSHIBA TEC CORPORATION All rights reserved WIRE HARNESS CONNECTION DIAGRAMS 10 2 ...
Страница 677: ......
Страница 678: ......