8
© 2015 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
ERROR CODE AND TROUBLESHOOTING
8 - 241
[F200] Data Overwrite option (GP-1070) disabled
[F500] HD partition damage
[F510] Application start error
Main memory
•
Check the installation
•
Main memory check
Parts to be replaced
Remark
Main memory
SYS board
Classification
Contents
Other service call
Data Overwrite option (GP-1070) disabled
Check Item
Measure
Setting
Perform firmware installation (all firmware: OS, HDD, SYS,
PFC Firmware, Engine Main Firmware, and Scanner
Firmware) with the USB media.
*
When the function of the Data Overwrite option (GP-
1070) is deleted from the equipment, the service call
“F200” occurs.
Perform 08-3840 to install the Data Overwrite Enabler (GP-
1070).
*
If F200 occurs while High (“3”) is set for the security
level (08-8911), it cannot be released by installing the
firmware using the USB media. Install the Data
Overwrite Enabler (GP-1070) by 08-3840.
Classification
Error item
Other service call
The file system is abnormal.
Check item
Measures
Setting
•
Diagnose the file system with [5] + [C] + [Start]
1. Check
F/S, and then recover the problem partition with [5] + [C] +
[Start]
2. Recovery F/S.
•
If it still is not recovered by performing the above, reinstall
the software after formatting the HDD with [3] + [C] +
[START] -> 3: Format HDD.
Classification
Error item
Other service call
The application fails to start.
Check item
Measures
Setting
1. Reboot.
2. If it has still not recovered, reinstall the HDD software.
3. If it still persists after step 2, perform [3] + [C] + [Start] -> 3,
and then reinstall the HDD software.
Note: User data will be deleted when [3] + [C] + [Start] -> 3 is
performed.
Check Item
Measure
Содержание E-STUDIO2008A
Страница 7: ......
Страница 24: ...e STUDIO2008A 2508A 3008A 3508A 4508A 5008A 2015 TOSHIBA TEC CORPORATION All rights reserved CONTENTS 12 ...
Страница 26: ...e STUDIO2008A 2508A 3008A 3508A 4508A 5008A 2015 TOSHIBA TEC CORPORATION All rights reserved FEATURES 1 2 ...
Страница 384: ...e STUDIO2008A 2508A 3008A 3508A 4508A 5008A 2015 TOSHIBA TEC CORPORATION All rights reserved SELF DIAGNOSTIC MODE 5 66 ...
Страница 484: ...e STUDIO2008A 2508A 3008A 3508A 4508A 5008A 2015 TOSHIBA TEC CORPORATION All rights reserved SETTING ADJUSTMENT 6 100 ...
Страница 988: ...e STUDIO2008A 2508A 3008A 3508A 4508A 5008A 2015 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 11 28 ...
Страница 1002: ...e STUDIO2008A 2508A 3008A 3508A 4508A 5008A 2015 TOSHIBA TEC CORPORATION All rights reserved BACKUP FUNCTION 12 14 ...
Страница 1008: ...e STUDIO2008A 2508A 3008A 3508A 4508A 5008A 2015 TOSHIBA TEC CORPORATION All rights reserved EXTERNAL COUNTERS 13 6 ...
Страница 1015: ......
Страница 1016: ...1 11 1 OSAKI SHINAGAWA KU TOKYO 141 8562 JAPAN ...