8
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO2006/2306/2506/2007/2307/2507/2303A/2303AM/2803AM/2309A/2809A
ERROR CODE AND TROUBLESHOOTING
8 - 85
8.4.18
Image dislocation in feeding direction
Fig.8-20
Defective area
Step
Check items
Prescription
Scanner/Printer
adjustment
1
Have the printed images been
dislocated in the same manner?
Adjust the position of the leading
edge of paper in the Adjustment
Mode.
Registration roller
2
Is the registration roller dirty, or the
spring detached?
Clean the registration roller with
alcohol.
Securely attach the springs.
3
Is the registration roller working
properly?
Adjust or replace the gears if they are
not engaged properly.
Feed clutch
4
Is the feed clutch working properly?
Check the circuit or feed clutch, and
replace them if necessary.
Pre-registration guide
5
Is the pre-registration guide installed
properly?
Install the guide properly.
Feeding direction
Содержание E-STUDIO2006
Страница 14: ......
Страница 729: ......