ERROR CODE AND TROUBLESHOOTING
8 - 75
8.4.9
White banding or white void (in the feeding direction)
Fig.8-11
Defective area
Step
Check items
Prescription
Scanner
1
Is there a foreign matter on the light
path?
Remove the foreign matter.
2
Are the original glass (especially the
position of shading correction plate)
and CIS unit dirty?
Clean them.
Transport path
3
Does the toner image contact with
any foreign matter before the paper
enters the fusing section after the
separation?
Remove the foreign matter.
Discharge LED
4
Is any of the discharge LEDS off?
Replace the discharge LED.
Cleaner
5
Is there any foreign matter, which
contacts the drum on the cleaner
stay?
Remove the foreign matter.
Toner cartridge
6
Is the adhered foreign matter
blocking the laser light path?
Remove the foreign matter.
Developer unit
7
Is the floated lid of the developer
bottle blocking the laser light path?
Check the lid and place it properly.
8
Is the developer material transported
properly?
Remove the foreign matter if there is
any.
9
Is there any foreign matter between
the doctor blade and the developer
sleeve?
Remove the foreign matter.
10
Is there a foreign matter or dew on
the drum seal?
Remove the foreign matter or dew.
11
Is the upper drum seal of the
developer unit in contact with the
drum?
Correct the position of the drum seal
or replace it.
Feeding direction