ERROR CODE AND TROUBLESHOOTING
8 - 274
8.4
Other errors
8.4.1
Equipment operation disabled after the installation of option(s)
Check if the optional board is installed properly.
8.4.2
Wireless LAN connection disabled
The connection state and settings of the Wireless LAN can be checked with [USER FUNCTIONS]
→
[ADMIN]
→
[WIRELESS LAN]
→
[SETTING CHECK].
Confirm the settings with the administrator.
•
“NIC INITIALIZING” does not disappear at the time of the power being turned ON and it disappears
after 6 minutes with the NIC initializing time-out. In this case, the connection to the Wireless LAN did
not succeed even though “NIC INITIALIZING” disappears.
•
The connection to the Wireless LAN cannot be made if the Access Point to be connected is not
found or security settings are not correct.
8.4.3
"Invalid Department Code" is displayed
Log in to TopAccess as an administrator, select [Authentication] on the [User Management] tab, and
then check whether Department Setting is enabled or disabled.
Department Setting is enabled:
•
Log in to TopAccess as an administrator, select [Authentication] on the [User Management] tab, and
then check User Management Setting.
•
Confirm the settings of 08-3805 in the setting mode.
Department Setting is disabled:
•
Log in to TopAccess as an administrator, select [Authentication] on the [User Management] tab, and
then check User Management Setting.
8.4.4
Paper folded on the leading edge
If the leading edge of B4, B5 or B5-R paper is folded when it exits, check the following items.
•
Check if the rear and side guides of the drawer or the side guide of the bypass tray correspond to
the paper size.
8.4.5
Toner cartridge unrecognized
If the toner cartridge is not recognized, check the following.
•
Check that there is no access abnormality to the toner cartridge IC chip.
P. 8-147 " [C911] Toner cartridge IC chip access board abnormality"
8.4.6
Ethernet disabled in half-duplex communication
The Ethernet of this equipment does not support half-duplex communication.
When the port setting of the switch is fixed at half-duplex communication, use any of 10/100/1000
Mbps, full-duplex fixed communication mode or auto-negotiation function.
In addition, select the setting of the equipment corresponding to that of the switch.
([ADMIN] > [NETWORK] > [ETHERNET])
Check the set communication speed as follows if required:
[ADMIN] > [NETWORK] > [ETHERNET]
Содержание e-studio 2555c
Страница 6: ......
Страница 10: ......
Страница 24: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FEATURE 1 2 ...
Страница 426: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved SELF DIAGNOSTIC MODE 5 60 ...
Страница 1008: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 11 24 Fig 11 14 ...
Страница 1024: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 11 40 ...
Страница 1038: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved BACKUP FUNCTION 12 14 ...
Страница 1044: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved EXTERNAL COUNTERS 13 6 ...
Страница 1550: ......
Страница 1557: ......
Страница 1558: ...1 11 1 OSAKI SHINAGAWA KU TOKYO 141 8562 JAPAN ...