ERROR CODE AND TROUBLESHOOTING
8 - 90
[EA2D] Paper transport jam in the Finisher (Sub-path sensor)
MJ-1036
[EA2E] Paper transport remaining jam in the Finisher (sub-path sensor)
MJ-1036
Classification
Error content
Paper jam in finisher section
Paper transport jam in the Finisher (Sub-path sensor)
Probable cause
Checking and measures
2nd transport motor (M4)
abnormality
Check if the electrical continuity of the coil is normal. If electricity is
not conducted, replace the motor.
Entrance path sensor (S19)
abnormality
Measure the voltage on TP86 on the finisher control PC board
(FIN). Then check that the measured voltage is 1V or lower when
not shielded and within the range of 3.3V
±
5% when shielded. If the
voltage does not fall within the range mentioned, replace the
sensor.
Sub-path sensor (S8)
abnormality
Measure the voltage on TP85 on the finisher control PC board
(FIN). Then check that the measured voltage is 1V or lower when
not shielded and within the range of 3.3V±5% when shielded. If the
voltage does not fall within the range mentioned, replace the
sensor.
Stationary tray full detection
sensor (S11) abnormality
Measure the voltage on TP26 on the finisher control PC board
(FIN). Then check that the measured voltage is 1V or lower when
not shielded and within the range of 3.3V±5% when shielded. If the
voltage does not fall within the range mentioned, replace the
sensor.
Faulty cables and connectors
Check if the electrical continuity between the connector terminals is
normal. If electricity is not conducted, replace the connector.
(Finisher control PC board (FIN): CN6, CN10, CN14, CN22)
Finisher control PC board
(FIN) abnormality
If the error still occurs after replacing the sensor and the connector,
replace the finisher control PC board (FIN).
Classification
Error content
Paper jam in finisher section
Paper transport remaining jam in the Finisher (sub-path sensor)
Probable cause
Checking and measures
Entrance path sensor (S19)
abnormality
Measure the voltage on TP86 on the finisher control PC board
(FIN). Then check that the measured voltage is 1V or lower when
not shielded and within the range of 3.3V
±
5% when shielded. If the
voltage does not fall within the range mentioned, replace the
sensor.
Sub-path sensor (S8)
abnormality
Measure the voltage on TP85 on the finisher control PC board
(FIN). Then check that the measured voltage is 1V or lower when
not shielded and within the range of 3.3V±5% when shielded. If the
voltage does not fall within the range mentioned, replace the
sensor.
Содержание e-studio 2555c
Страница 6: ......
Страница 10: ......
Страница 24: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FEATURE 1 2 ...
Страница 426: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved SELF DIAGNOSTIC MODE 5 60 ...
Страница 1008: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 11 24 Fig 11 14 ...
Страница 1024: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 11 40 ...
Страница 1038: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved BACKUP FUNCTION 12 14 ...
Страница 1044: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved EXTERNAL COUNTERS 13 6 ...
Страница 1550: ......
Страница 1557: ......
Страница 1558: ...1 11 1 OSAKI SHINAGAWA KU TOKYO 141 8562 JAPAN ...