D-VR5SU/D-VR5SC
PREVENTIVE CHECKS AND SERVICE INTERVALS
The following standard table depends on environmental conditions and usage.
Parts replacing time does not mean the life span for individual parts.
Also, long term storage or misuse may cause transformation and aging of rubber parts.
The following list means standard hours, so the checking hours depends on the conditions.
: Clean
: Check it and if necessary, replace it.
Time
Parts Name
500
hours
1,000
hours
Notes
1,500
hours
2,000
hours
2,500
hours
Audio Control Head
Full Erase Head
(Recorder only)
Capstan Belt
Pinch Roller
Capstan DD Unit
Loading Motor
Tension Band
Capstan Shaft
Tape Running
Guide Post
Cylinder Unit
Clean those parts in
contact with the tape.
Clean the rubber, and parts
which the rubber touches.
Replace when rolling
becomes abnormal.
Clean the Head
T Brake Band
Clutch Ass’y
Idler Arm Ass’y
C3-1
CONFIRMATION OF HOURS USED
PLAY/REC total hours can be checked on the screen.
Total hours are displayed in 16 system of notation.
NOTE: If you set a factory initialization, the total hours is reset to “0”.
1.
2.
3.
4.
Connect the set to TV Monitor.
Turn on the POWER, and set to the VCR mode.
Press both CH UP button on the set and the FF button on the set for more than 2 seconds.
The Fig. 1 screen will appear on TV Monitor.
After the confirmation of using hours, turn off the power.
Initial setting content of MEMORY IC.
PLAY/REC total hours.
= (16 x 16 x 16 x thousands digit value)
+ (16 x 16 x hundreds digit value)
+ (16 x tens digit value)
+ (ones digit value)
Fig. 1
Initial setting data check sum.
Romcorrection data check sum.
MICON Version
OEC0161A 118B
INIT 00 0E
DATA 10D3
ROM 6DC4