04/08/27
Ver1.01
*本資料に記載された内容は予告なく変更する場合がありますので、予めご了承下さい。
8
(5) Multiple-shutter Mode Setting
Exposure is done during the one frame period which comes immediately after TRIG IN. Images are
output at the readout signal (E.VD) timing. If the exposure is made more than one time before the
readout signal input, superposed images are output. After video-output, it goes back into the normal
operation (= shutter OFF) if the TRIG terminal voltage stays in LOW for 2V or longer consecutively,
regardless of which RTS mode is currently set in.
-1 Fix mode
-1 Pulse mode
A+B
A
露光時間
(TRIGパルス幅+ 15μs)
露光信号
TRIG
CCD(露光)
読み出し信号
E.VD
映像出力
HD
B
WEN
VD
露光時間
(TRIGパルス幅+ 15μs)
20μs
5.0μs
20μs
5.0μs
A+B
A
露光時間
(内部DIP-SWにて設定)
露光信号
TRIG
CCD(露光)
読み出し信号
E.VD
映像出力
HD
B
露光時間
(内部DIP-SWにて設定)
WEN
VD
5.0μs
5.0μs